Warning: remember to stand over a bin every time you clean the dust tray.
REMOVE THE DUST TRAY (13)
• Withdraw the tube (19) from the vacuum opening (10) - Fig.2.
• Remove the dust tray (13) from its housing (7) : take the tray handle (13a) and remove the tray – fig. 14.
1. EMPTY THE DUST TRAY
Important: Empty the dust tray (13) after each use.
• Press on the opening lever (13c) – fig. 15a—and then remove the lid – fig. 15b.
• Empty the tray over a bin – Fig. 16.
• Make sure that no dust remains inside the tray.
• Place the lid back: place the stops in their slots – fig. 17a – and close the lid – fig. 17b.
• Replace the tray (13) in its compartment (7) – Fig. 18.
2. CLEANING THE BLACK FOAM FILTER (14A)
Important! To optimise the performance of your vacuum cleaner, make sure you clean the foam (14a)
each time you empty the dust tray (13).
• Pull simultaneously on the opening clips (13d) of the HEPA filter case - Fig.19.
• Separate the black foam filter (14a) from the HEPA filter (14b) - Fig. 20.
• Wash the black foam filter (14a) under the tap, squeeze it out like a sponge and leave to dry for 12 hours
- fig. 21.
• Once the foam is completely dry, assemble the HEPA filter case (14): black foam filter (14a) and HEPA fil-
ter (14b) under the dust tray (13) – Fig. 22, then replace the dust tray inside its compartment (7) – Fig. 18.
Warning!
The black foam filter (14a) should only be put back into the appliance when it is completely dry. You
can use your vacuum cleaner while the black foam filter (14a) is drying by using the replacement
black foam filter (14abis).
3. CLEAN THE DUST TRAY (13) AND THE AIR/DUST SEPARATOR (15)
Important: Clean the dust tray (13) and the dust separator (15) every month.
• Press on the opening lever (13c) – fig. 15a—and then remove the lid – fig. 15b.
• Empty the tray over a bin – Fig. 23.
• Unlock the HEPA filter case (14) by simultaneously pulling on the opening clips (13d) located at either
end of the dust tray – Fig. 24.
• Remove the HEPA filter case (14) – Fig. 25.
• Turn the compartment over and place the accessory (18b) into the lock slot of the air/dust separator base
(17) - fig 26.
• Open, making sure to turn in the proper sense for unlocking (
• Remove the dust separator base (16) - Fig. 28.
• Unclip then remove the air/dust separator (15) by turning it in the unlocking direction (
• Then rinse the dust tray (13), the air/dust separator base (16) and the air/dust separator (15) with soapy
water – Fig. 30.
• Dry them with a cloth – Fig. 31.
• Once dry, replace then clip the air/dust separator (15) on the air/dust separator base (16), following the
right sense for locking (
• Place them back on the dust tray (13) - fig 33.
• Place the accessory (18b) into the lock slot of the air/dust separator base (16) - fig 34.
• Close, making sure to turn in the proper sense for locking (
• Clip the HEPA filter case (14) (black foam filter (14a) + HEPA filter (14b)) onto the tray – Fig. 36.
• Replace the tray (13) in its compartment (7) – Fig. 18.
* According to model : this piece or accessory is specific to
certain models or can be bought separately.
) – Fig.32.
) – Fig.27.
) – Fig.35.