5.14 Registers
All data values extend over 2 MODBUS registers and can only be processed as a whole.
Float register (4 bytes)
Address
Value
0000
Main counter
hex
0002
Secondary counter
hex
0004
Preset 1
hex
0006
Preset 2
hex
0008
Multiplication factor
hex
000A
Division factor
hex
000C
Store set value
hex
Perform set
000E
hex
function
Preset 1 sign
0010
hex
setting
Decimal point
0012
hex
setting
0014
Status
hex
r/o:
Read-only access
r/w:
Read and write access
-/w:
Write access
Access Description
Writing any value resets the main
r/w
counter.
Writing a value resets the main
r/w
counter and the secondary
counter.
r/w
Preset 1
r/w
Preset 2
-/w
Multiplication factor
-/w
Division factor
Storage of the set value
-/w
(no setting is performed)
Setting
-/w
(writing any value performs the
setting)
Byte 1: Sign value
Byte 2: 0
-/w
Byte 3: 0
Byte 4: 0
Byte 1:decimal places
Byte 2: 0
r/w
Byte 3: 0
Byte 4: 0
Byte 1: bit1: output 1
bit2: output 2
Byte 2: bit1 - bit4: main counter
r/o
bit5 - bit8: secondary
Byte 3: 0
Byte 4: 0
Note
Sign values:
1: + values
2: -- values
3: +/- values
Decimal places:
0: 0 decimal places
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
4: 4 decimal places
5: 5 decimal places
Output:
1: ON
0: OFF
Counter status:
counter
0: counter status: regular
1 :counter status: overflow
2: counter status: underflow
Page 11 | ENG