Requirements for Compliance with UL294 6th
Edition
This section contains information and instructions
required for UL compliance. To make sure the
installation is UL compliant, follow the instructions
below in addition to the general information and
instructions provided throughout this document. In
cases where pieces of information contradict each
other, the requirements for UL compliance always
replace general information and instructions.
Performance Levels for Access Control
This section contains performance level information
required for UL 294 compliance.
Feature
Destructive Attack Test
Line Security
Endurance
Standby Power
Safety Instructions
•
The Axis product shall be installed and serviced by
a factory trained professional.
•
The Axis product shall be installed within the
protected premises (secured area).
•
The Axis product shall be mounted indoors.
Outdoor use has not been evaluated or approved
by UL.
•
All interconnecting devices shall be UL Listed and
Class 2 low-voltage power limited.
•
All wiring methods shall be performed in
accordance with NFPA70, local codes and
authorities having jurisdiction.
•
When the Axis product has reached the end of its
useful life, dispose of it according to local laws and
regulations. The product should not be disposed
of together with household or commercial waste.
See Disposal and recycling on page 3 .
•
Battery
-
-
-
Level
I
I
IV
I
The 3.0 V lithium battery
used by the Axis product
is a UL Recognized
component. (Type: BR2032,
diameter: 20 mm (0.78 in),
manufacturers: Rayovac,
Panasonic). The following
battery type is also a UL
Recognized component: Type
CR2032, manufacturers:
Fuji, Maxell, Renata, Varta,
Panasonic, JHIH
Users shall not replace
the battery. If the battery
needs replacing, a factory
trained service professional
shall contact Axis support
at www.axis.com/techsup for
assistance.
Used batteries shall be disposed
of according to local laws and
Specifications
•
Operating Conditions
-
-
-
•
Wire area
-
-
•
Connectors
-
-
-
-
regulations, which may vary
from state to state. Waste
BR/CR lithium cells are neither
listed nor exempted from
the USEPA hazardous waste
regulations. Waste lithium
batteries can be considered
reactive hazardous waste if
there is a significant amount
of unreacted, or unconsumed
lithium remaining. For
information about how to
dispose of used lithium
batteries, contact your local
authority for waste disposal.
Classification
IEC 60721-4-3 Class 3M3
Temperatures
-30°C to 55°C (-22 °F to 131 °F).
Humidity 20-85% RH (non-
condensing)
UL Listed or R/C AWM wires
that have an conductor gauge
range of AWG 22–14 shall be
used.
The minimum conductor gauge
for connection between the
power sourcing equipment
(PSE) or power injector and
the powered device (PD) is
26 AWG.
This product is not intended
for outside wiring as covered
by Article 800 in the National
Electrical Code, NFPA 70.
Power Connector – For UL
security applications, the
product shall be powered by a
UL 294 Listed or UL 603 Listed
Class 2 low-voltage power
SELV and limited power supply
that is capable of 4 hours of
standby power.
External power to relays - If
the relays are connected to
an external power source this
must be UL 294 Listed or UL
603 Listed Class 2 low-voltage
power SELV and limited power
supply that is capable of 4
hours of standby power.
Network Connector – Power
over Ethernet (PoE) shall be
supplied by a UL 294 Listed
Power over Ethernet IEEE
802.3af/802.3at Type 1 Class
3 or Power over Ethernet Plus
(PoE+) IEEE 802.3at Type 2
Class 4 power limited injector
that provides 44–57 V DC,
15.4 W / 30 W and 4 hours of
standby power.
The products shall not be
installed in the fail-secure