POLAR-AIRE VF-9WFD Instrucciones De Operación Y Seguridad página 4

Ventilador doble para ventana de 9 pulgadas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NOTES:
Remove Snap-on Feet when using the product as a window fan.
This product is designed to fit double-hung, casement, or vertically-sliding
windows.
Minimum window space opening is 23 inches (58 cm) x 11 inches (28 cm).
1. Ensure all four LOCK/UNLOCK Switches
for the Expandable Panels (see Fig. 2)
are set to the UNLOCK position.
2. Open the window where the fan is
to be placed. Raise the lower sash to
make an opening of at least 11 inches
(28 cm) high.
3. Center the Fan on the windowsill in
the window opening with the Control
Panel facing the inside of the room.
NOTE: Make sure the lower edge of the Fan is positioned over the
windowsill cap.
4. Grasp the Fan handle and gently lower the window sash onto the top
edge of the Fan.
NOTE: Make sure the window sash rests between the Sash Holders
protruding from the top edge of the Fan.
5. Pull out the Expandable Panels so they reach the side edges of the
window.
6. Once the fan is securely in place, slide all four LOCK/UNLOCK Switches to
the LOCK position.
WARNING: Do not lift the sash of a double-hung window while the Fan
is in operation, as there may be a risk of serious personal injury and/or
product damage.
6
To Use
WARNING: Do not expose this product to rain, snow, or hail, as an electrocution
hazard exists and serious personal injury and/or product damage may occur.
1. Plug the Fan into a standard 120-volt AC electrical outlet, the fan will stay on
standby mode.
2. Choose an airflow direction by sliding the FRESH AIR/EXHAUST Switches to the
desired positions.
NOTICE:
Never change the airflow direction (Intake, Exhaust, or Air
Exchange) while the Fan is operating.
NOTES:
-
Intake: Air is pulled into the room from the outside.
-
Exhaust: Air is pushed from inside the room to the outside.
-
Air Exchange: One Fan is set on "Intake", pulling fresh air into the room,
while the other Fan is set on "Exhaust", simultaneously pushing stale air
from inside the room to the outside.
3. To turn on the fan, press the power button( ) located on the left side of the
control panel. The fan will start on "HIGH" speed (Default Setting), and
"HIGH" speed indication light illuminates. Press the fan speed control button
( ) located on the right side of the control panel repeatedly to change fan
speed from "HIGH-MED-LOW", the indication light will illuminate accordingly.
Thermostat default setting is "OFF", three temperature indication lights are
"OFF".
4. THERMOSTAT
Choose from 60F, 75F or 90F settings by performing the following function:
60F: Press the Thermostat Control Button ( ) once.
75F: Press the Thermostat Control Button ( ) twice.
90F: Press the Thermostat Control Button ( ) a third time.
The temperature indication light will illuminate accordingly. Press the
Temperature Control Button a fourth time to turn the temperature feature off,
and all temperature indication lights will turn off.
NOTE: The fan will turn off if the room temperature drops below setting and
will turn on again if the room temperature climbs above setting.
7
Tabla de contenido
loading

Productos relacionados para POLAR-AIRE VF-9WFD

Tabla de contenido