Operation
USING THE GENERATOR
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals
on the AC output receptacles. The system ground is
connected to the AC neutral wire (the neutral is
bonded to the generator frame).
Special
Requirements
There may be Federal or State Occupational Safety
and Health Administration (OSHA) regulations, local
codes, or ordinances that apply to the intended use of
the generator. Please consult a qualified electrician,
electrical inspector, or the local agency having
jurisdiction.
Connecting
to a Buiiding's
Electrical
System
Connections for standby power to a building's electrical
system must be made by a qualified electrician. The
connection must isolate the generator power from
utility power, and must comply with all applicable laws
and electrical codes.
WARNING
When using generator for backup power, notify utility
company. Use approved transfer equipment to isolate
generator from electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp
or highly conductive area, such as metal decking or steel
work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are
worn, frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while
standing in water, while barefoot, or while hands or feet
are wet.
DO NOT allow unqualified persons or children to operate
or service generator.
Generator
Location
Generator Clearance
,_
WARNING
Keep at least 5 ft. (152 cm) clearance on all sides of
generator including overhead.
Place generator in a well ventilated area, which will
allow for removal of deadly exhaust gas. DO NOT place
generator where exhaust gas could accumulate and
enter inside or be drawn into a potentially occupied
building. Ensure exhaust gas is kept away from any
windows, doors, ventilation intakes or other openings
that can allow exhaust gas to collect in a confined area
(Figure 3). Prevailing winds and air currents should be
taken into consideration when positioning generator.
Using a generator
indoors WILL KILL YOU
IN MINUTES.
Exhaust
contains
carbon
monoxide,
a
poison
gas you cannot
see or smell.
NEVER use in the home
or in partly enclosed
areas SUChas garages.
[]
IONLY use outdoors and
ifar from open windows,
doors, and vents.
Exhaust Port
O