WIRING THE CHARGING STATION
1. Install a dedicated, 240VAC or 208VAC, 60Hz, grounded branch
circuit with a 20A circuit breaker or fuse. This circuit should
comply with the NEC and any local codes that apply. The circuit
must reach the entry port on the charger base, and have 12" of
extra wire to terminate inside the charger.
2. Determine where the circuit will enter the Charger and
drill through the housing at the entry location to accept the
incoming cable.
Rear feed option – If one of the rear entry locations was
selected, thread appropriate cable clamp or fitting into provided
¾ NPT threaded hole, feed cable through clamp and fasten
cable.
Bottom feed option – If the bottom feed location was chosen
for the incoming cable, a 1" NPT threaded is supplied (Figure 6).
3. Strip ends of incoming power conductors 1/2" and connect
them securely to the leads of the Charger using the appropriate
wire nuts.
WARNING: TO AVOID RISK OF FIRE OR SHOCK WHICH MAY
RESULT IN SERIOUS INJURY OR DEATH TURN OFF
POWER TO CIRCUIT BY USING BREAKER OR FUSE
AT THE SERVICE ENTRANCE BEFORE WIRING.
VERIFY THAT POWER HAS BEEN REMOVED BY
TESTING WITH A CIRCUIT TESTER.
CAUTION: USE ONLY COPPER OR COPPER CLAD WIRE WITH
THIS PRODUCT. DO NOT USE THIS DEVICE WITH
ALUMINUM WIRE.
Illustration of unit showing intersection of 2 lines on wall through
the hole drilled in the back of the unit.
Illustration of unit showing entry port on the bottom of
the charger base.
Figure 5
Figure 6
4. Reconnect 2 jumper connectors to circuit boards (Figure 3).
5. Reassemble cover to base using 8 Torx head screws.
Attach decorative panels to cover (Figure 1).
6. Close circuit breaker or fuse to energize the charging unit.
7. Verify the correct installation of the charging unit by reviewing
the indicator lights. There are three sets of indicator lights that
communicate the status of the charging station (Figure 7).
a. Charge Indicator – Four green lights indicate station is ready
to charge
b. AC Present Indicator – Green light indicates station is ready
to charge
c. Fault Indicator – Green light indicates station is ready to
charge
If the indicator lights on your charging station do not match the
description above please consult the Troubleshooting section of the
User Guide.