Attach Dome Cover
1. Attach the view protection to the camera unit.
2. Make sure the gasket in the dome cover is clean and sits securely in place.
3. Place the dome cover on the unit casing and tighten the screws to 2.0 Nm (1.5 lb ft)
with the supplied TR20 screw bit.
4. Remove the protective film from the dome cover.
Access the Product
AXIS IP Utility and AXIS Camera Management are recommended methods for finding Axis products
on the network and assigning them IP addresses in Windows®. Both applications are free and can
be downloaded from www.axis.com/techsup
The product can be used with most operating systems and browsers. We recommend the following
browsers:
•
Internet Explorer
®
•
Safari
with OS X
TM
•
Chrome
or Firefox
For more information about using the product, see the User Manual available at www.axis.com
Set focus and zoom
These instructions are valid if you have selected Optical zoom for installation during camera
startup.
1. Go to Setup > Video & Audio.
2. On the focus page go to the Basic tab.
3. Set the zoom level using the slider.
Note
Movements in front of the camera should be avoided when performing autofocus.
4. Click Perform autofocus.
5. If the result is not satisfactory, go to the Advanced tab.
On the Advanced tab, focus can be adjusted manually:
1. Click Open iris to open the iris to its maximum position. This gives the smallest depth of
field and provides the best conditions for focusing.
2. Focus is set in the Focus window. Use the mouse to move and resize the focus window.
3. Click in the Focus position bar to focus on a desired location.
4. When satisfied, click Enable iris to enable the iris.
AXIS Q3505-SVE Mk II Network Camera
®
®
with Windows
®
®
with other operating systems.
21