Cables; Operating Conditions - Axis Q86 Serie Guia De Instalacion

Ocultar thumbs Ver también para Q86 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 103
AXIS Q86 Series
This table is only valid for the 24 V AC and the 24 V DC power connectors.
Position
24 V AC
1
Protective earth
2
24 V AC Phase
3
24 V AC Neutral
4
Not connected

Cables

Cable thickness
The cable diameter, when using cable gaskets provided with the product, should be in the range of
5 to 11 mm (0.2 to 0.4 in).
NO
NO
NO TICE
TICE
TICE
• Use cables that keep within the specified cable area
• Select cables in compliance with your local regulations
• Make sure all cable holes are properly sealed
• Use cable gaskets or cable glands that match both the cable hole and the cable area
For information about accessories, such as cable gaskets and cable glands that allow for other
cable areas, see www.axis.com

Operating conditions

The Axis product is intended for indoor and outdoor use.
Temperature
Operation: -40 °C to 60 °C
(-40 °F to 140 °F)
24 V DC
Protective earth
+ 24 V
0 V
Not connected
Humidity
10–100% RH (non-condensing)
34
Tabla de contenido
loading

Este manual también es adecuado para:

Q8641-e ptQ8642-e pt

Tabla de contenido