M 780672000203022015
INSTALLATION OF THE ON/OFF SWITCH
The on / off switch for the Wasteminator II is vacuum-controlled, and must therefore not be
connected to electrical power, but is connected to the Wasteminator II with the included rubber
hose.
The on / off switch is installed as follows:
1
Find a suitable location for the on/off
switch and drill a hole measuring Ø 32-34
mm.
Install the on/off switch in the hole.
THERMEX WASTEMINATOR 69
2
Attach the rubber hose to the on/off
switch and to the bottom of the
Wasteminator II.
NOTE: the rubber hose must be fixed
with the plastic nut on the bottom of
the Wasteminator II.