Grundfos DME Instrucciones De Instalación Y Funcionamiento página 16

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Setting range
U.S. Gallons
0.0000067 -
DME 2
1.32 gallons/batch
0.00018 -
DME 8
3.96 gallons/batch
0.00029 -
DME 12
6.34 gallons/batch
0.00053 -
DME 19
9.77 gallons/batch
0.00132 -
DME 48
25.36 gallons/batch
Only values corresponding to complete dosing
strokes (according to the calibration factor) can be
selected.
Example: If the calibration factor is 23.3 (= 0.233 ml/
stroke), the minimum settable value in timer or batch
mode will be 0.233 ml -> the next will be 0.466 ml ->
the next will be 0.699 ml, etc.
These steps will continue up to a value correspond-
ing to 100 dosing strokes. Above this value, the set-
ting range has standard steps as in other operating
modes.
If the calibration factor is changed after setting of
timer or batch mode, the pump will automatically
recalculate a new amount of dosing strokes per
batch and change the display value to the nearest
possible value compared to the first one set.
16
Metric
0.23 ml/batch -
5 l/batch
0.69 ml/batch -
15 l/batch
1.11 ml/batch -
24 l/batch
2.04 ml/batch -
37 l/batch
5.3 ml/batch -
96 l/batch
Set quantity
per batch
Set IN value
in minutes
Set IN value
in hours
Set IN value
in days
Set NX value
in minutes
Set NX value
in hours
Set NX value
in days
Fig. 12 Timer mode