INSTALLATION INSTRUCTIONS
C-WM-A-WLMO Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3.
Suitable for Wet Locations.
Adspte pour les Endroits Mouiles.
4.
WALL MOUNT ONLY.
INSTALLATION MURALE SEULEMENT.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
http://lighting.cree.com/warranty
Document:
LPN00669X0001A0_A
Created By:
TMT
MOUNTING
1.
Remove the lens by removing the 3 screws securing it to the
fixture back plate. Set screws aside for reinstalling later.
2.
Remove the 2 hex nuts above the LED board to separate the
fixture back plate from the rear mounting bracket. See Figure 1 on
the back page. Set nuts aside for reinstalling later.
NOTE: Do NOT touch the LED board during the installation
process.
3.
Attach fixture mounting bracket to junction box using hardware
supplied by others. Rotate crossbar of bracket so threaded studs
located on crossbar are horizontally positioned relative to each
other. Tighten two center screws on mounting bracket to fix
position of bracket. See Figure 1 on the back page.
4.
Make wiring connections per the Electrical Connections section.
5.
Slide fixture back plate over 2 threaded studs on mounting
bracket. For wet locations, a high grade caulking material, such
as silicone rubber, should be used between back gasket on fixture
back plate and mounting surface. See Figure 1 on the back
page.
6.
Secure back plate to mounting surface by tightening nuts removed
in Step 2 above.
7.
Replace lens by tightening the lens screw that were removed in
Step 1. Do Not overtighten screws to prevent damage to lens.
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no
wires are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no
wires are pinched.
|
1-800-236-6800