inside the tap until the correct setting is obtained.
On gas valves provided with adjustment screw on the valve body (fig.15):
√ Turn the screw "A" to the correct setting with a screwdriver.Normally for G30 gas, fully tighten the adjustment screw.
LUBRICATION OF THE GAS TAPS
If the gas tap becomes stiff, it is necessary to dismount it accurately clean it with gasoline and spread a bit of special grease resistant to
high temperatures on it.
The operations must be executed by a qualified technician.
ELECTRICAL SECTION
In the case of installation over a built-in electric oven, the electrical connections for the built-in gas hob and oven should be independent,
not only for safety purposes, but also to facilitate removal of one or both in the future.
IMPORTANT: Connection to the electric power supply must be carried out by a qualified technician and following the appropriate
safety regulations;
DETAILS
Before carrying out the connection to the power supply, the voltage rating of the appliance(stamped on the appliance identification
plate) must be checked for correspondence to the available mains supply voltage, and the mains electric wiring should be capable of
handling the hob's power rating (also indicated on the identification plate);
The power point must be connected to a suitbale earth wiring, in conformity to current safety regulations.
The colours of the wires in the built-in gas hob power cable may not correspond with the colours marked on the terminals of your
electrical plug. The plug should in any case be wired as follows:
Connect the green/yellow wire to the terminal marked with the letter E or the earth symbol or coloured green/yellow;
Connect the blue wire to the terminals marked with the letter N or cloured black;
Connect the brown wire to the terminal marked with the letter L or coloured red.
It is possible to connect the appliance directly to the mains supply by means of a heavey duty switch with 3 mm minimum distance
between contacts.
The power supply cord must not touch against any hot surfaces and must be placed so that it's temperature does not exceed 75℃ at
any point along its length.
After having installed the appliance, the power switch or power plug must always be in a accessible position.
NOTE: for connections to the mains power supply, never use adapters, reductions or multiple power points as there may
overheat and catch fire.