GB
2. Identification
Type designation
Technical data
3. Technical data
3.1 Electrical data
Voltage:
Fuse:
Output:
Current consumption in normal mode:
Current consumption in bypass mode:
Type of protection:
Power supply:
3.2 Hydraulic data (with diesel fuel, 20 °C)
Delivery pressure:
Suction pressure:
Suction height:
Zero pump output:
Delivery output under ref. conditions:
Under other intake conditions, higher negative pressure values may be necessary, reducing delivery pressure
and therefore output (see paragraph 4.3 for correct specification).
3.3 Operating conditions
Temperature range:
Relative humidity:
14
Part number
138.1019.028
Cematic 12/40
{
40 l/min
12 V DC
18 A
120 W
12 VDC +/- 10%
25 A
120 W
18 A
24 A
IP 55
battery, or power pack with safety transformer
max. 1 bar
max. 0.3 bar
max. 2.5 m with foot valve
max. 2 m without foot valve
40 l/min
approx. 35 l/min
- 20 °C to + 60 °C
max. 90 %
Week/year of manufacture
Week 33/2012
1 bar
3800 rpm
IP 55
Fuse 25 A
Manufacturer