Thomas & Betts CSNMG-NG Manual De Instrucciones

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

WARNING
RISK OF SHOCK,
DISCONNECT POWER
BEFORE INSTALLATION.
Box and GFCI Installation
(Steps A Thru E)
A. Determine which of the round openings will be used for
the supply wiring. Liberally coat the threads on the round
plugs with sealant and install them rmly in the unused
openings (Fig. A).
B. The four small holes in the back of the metal box are for
attaching the mounting lugs. Select the two locations that
best suit your installation and attach the mounting lugs
using the 1/4" long screws. For most metal box
applications, you will mount the lugs diagonally from each
other (Fig. B).
C. Feed the supply wires into the box (Fig. C). Determine if
box is to be mounted vertically or horizontally. Attach the
box to the surface using 1" long screws.
D. Wire receptacle (Fig. D).
E. Push all wiring into the outlet box. Then attach the
receptacle to the box installing the 3/4" pan head screws
provided through the elongated slots (Fig. E).
Weatherproof Cover Installation
(Steps 1 Thru 4)
1. INSTALL WASP GUARD. Determine desired mounting
(Figures 1 & 2). Remove (break-out) knockout from bottom
PORT of base using pliers. Remove protective backing
from adhesive side of rubber WASP GUARD. Position and
place adhesive side on outside of curved rib in open
PORT. Carefully fold WASP GUARD along top surface and
secure to inside of curved rib in open PORT (see Figure 1,
2 & 3).
2. INSTALL BASE TO BOX.
Vertical Mounting (Figure 1) or Horizontal Mounting
(Figure 2).
NOTE: Position BASE with COVER HINGE on top and
open PORT on bottom. Loosen receptacle screws 9/16"
from receptacle strap (see Figure 1, Detail A). Place BASE
keyholes over receptacle screws (Figure 1, Detail B). Make
certain gasket overlaps box edges and tighten screws to
secure BASE.
3. INSTALL COVER. Place COVER onto BASE so that top
HINGE holes align and latch is engaged. Fully insert
HINGE PIN through top hole until it locks in place.
4. TURN ON POWER.
OPTION A: Alternative GFCI installation.
Verify receptacle is centered and securely fastened to box.
Drill out (4) pre-marked holes in BASE using 5/32" diameter
drill (Figure 4). Make certain gasket overlaps box edges.
Insert (4) furnished 3/4" long countersink head screws
and tighten to secure BASE (see Figure 1) (see steps 3 & 4).
OPTION B: Alternative GFCI installation (not pictured).
Verify GFCI is securely fastened to box. Insert (2) screws
(furnished) through top and bottom ROUND holes (Figure 1,
Detail B) in BASE into threaded holes in GFCI. Make certain
gasket overlaps box edges and tighten screws to secure
BASE (see steps 3 & 4).
© 2018 Thomas & Betts Memphis, TN.
All Rights Reserved.
www.tnb.com
CAUTION
BOX SHOULD BE INSTALLED BY A QUALIFIED
ELECTRICIAN IN COMPLIANCE WITH NATIONAL
AND LOCAL ELECTRICAL CODES.
FIG. A
Round Hole
See OPTION B
(2) Keyholes
Figure 1
Hinge Pin
Curved Rib
Around Port
Wasp Guard
HORIZONTAL MOUNTING
Figure 2
OPTION A
Drill through
4 holes using
5/32" drill
Vertical
Latch
Figure 4
Weatherproof GFCI Kits with Metallic and PVC Boxes
CSNMG-NG, S355P, CKPS-C-CN-PKIT, CKPS-W-CN-PKIT, CKPM-C-CN-PKIT,
CKPM-W-CN-PKIT, CKPL-C-CN-PKIT, 2CKPM-C-CN-PKIT, 2CKPL-C-CN-PKIT
CKPS-C-CN-KIT, CKPS-BR-CN-KIT, CKPS-W-CN-KIT, CKPM-BR-CN-KIT,
Mounting Lug
Plug
Box
Screw
FIG. B
WARNING
ELECTRICAL HAZARD!
TURN POWER OFF!
Cover
Cover
Hinge
Detail B
Screws
See OPTION A
Port
(Shown with
Wasp Guard installed)
Cover
Cover Hinge
Install
Port
Remove bottom
knockout
Horizontal
Latch
For 1-9/16" round
receptacle
remove curved
sections
Gasket on back
of Base
BASE
Back View
Cat. No. /
PVC BOX KITS:
METALLIC BOX KITS:
CKPM-W-CN-KIT
White
Wire
Silver
Screw
Ground
FIG. D
FIG. C
Wire
Detail A
Gasket
Hinge Pin
Base
VERTICAL MOUNTING
Fold here when
installing
Gasket
Base
Peel away
Backing
WASP
GUARD
Figure 3
Receptacle
Screws
Black
Wire
Brass
Screw
FIG. E
Receptacle
screws must
extend 9/16" from
receptacle strap
face to mount
cover
Receptacle
Strap Face
Outlet Box
RTA00671 D Page 1 of 4
loading

Resumen de contenidos para Thomas & Betts CSNMG-NG

  • Página 1 Weatherproof GFCI Kits with Metallic and PVC Boxes Cat. No. / PVC BOX KITS: CSNMG-NG, S355P, CKPS-C-CN-PKIT, CKPS-W-CN-PKIT, CKPM-C-CN-PKIT, CKPM-W-CN-PKIT, CKPL-C-CN-PKIT, 2CKPM-C-CN-PKIT, 2CKPL-C-CN-PKIT WARNING CAUTION METALLIC BOX KITS: RISK OF SHOCK, BOX SHOULD BE INSTALLED BY A QUALIFIED CKPS-C-CN-KIT, CKPS-BR-CN-KIT, CKPS-W-CN-KIT, CKPM-BR-CN-KIT,...
  • Página 2 Kits DDFT étanches avec boîte métallique et en PVC No. de catalogue / KITS BOITES EN PVC: CSNMG-NG, S355P, CKPS-C-CN-PKIT, CKPS-W-CN-PKIT, CKPM-C-CN-PKIT, CKPM-W-CN-PKIT, CKPL-C-CN-PKIT, 2CKPM-C-CN-PKIT, 2CKPL-C-CN-PKIT AVERTISSEMENT MISE EN GARDE KITS BOITES MÉTALLIQUES: RISQUE DE CHOC. LA BOÎTE DOIT ÊTRE INSTALLÉE PAR UN...
  • Página 3 Juegos de GFCI con cajas de metal y PVC a prueba de intemperie No. de Cat / KITS DE CAJA EN PVC: CSNMG-NG, S355P, CKPS-C-CN-PKIT, CKPS-W-CN-PKIT, CKPM-C-CN-PKIT, AVISO AVISO CKPM-W-CN-PKIT, CKPL-C-CN-PKIT, 2CKPM-C-CN-PKIT, 2CKPL-C-CN-PKIT KITS DE CAJA DE METAL: RIESGO DE DESCARGA ELÉCTRICA.
  • Página 4 English Français (Canada) Español THOMAS & BETTS CORPORATION THOMAS & BETTS CORPORATION GARANTÍA LIMITADA DE POR VIDA LIMITED LIFETIME WARRANTY GARANTIE À VIE LIMITÉE DE THOMAS & BETTS CORPORATION Thomas & Betts Corporation sells this product Thomas & Betts Corporation vend ce produit Thomas &...

Este manual también es adecuado para:

S355pCkps-c-cn-pkitCkps-w-cn-pkitCkpm-c-cn-pkitCkpm-w-cn-pkitCkpl-c-cn-pkit ... Mostrar todo