Technical Data; Operating Features - Seav LRX 2035 Manual De Instrucciones

Ocultar thumbs Ver también para LRX 2035:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
aware of fixing the cables in order to attach
them in a solid Way. Moreover, during the shell
drilling phase to let the power and connection
cables go through, and the cable glands assem-
bly, warning to Install everything in order to
maintain unchanged the IP-degree properties of
the box.
13) Mounting of a push button panel for manual
control must be done positioning the push but-
ton panel where the user is not in a dangerous
position.
14) The plastic box is lacking in anti-intrusion Tampere
connection In the removable part of the Switch, so
it is recommended the Assembly by the installer for
a major safety to the Alarm system.
15) The safety function, guaranteed by the electronic
unit, operates Only during the closure; so the open-
ing protection must be Guaranteed by independent
actions (havens or safety distance) From the control
circuit during the installation.
16) For a correct functioning of the radio receiver, if us-
ing one or More control units, the installation at a
minimum distance of at least 3 metres one from the
other is recommended.
Electronic control unit:
LRS 2035 Alarm
LRS 2035 SET Alarm - LRH 2035 Alarm
Comply with the specifications of the Directives
RED 2014/53/EU, EMC 2014/30/EU, LVD 2014/35/EU.

TECHNICAL DATA:

- Power supply
- Flashing light output
- Motor output
- Buffer battery input
- Alarm light output
- Power supply service output : 12 Vdc 5 W max.
- Safety and BTcontrols
- Working temperature
- Radio receiver
- Op. transmitters
- Max. TX codes in memory
- Board dimensions
- Box dimensions
- Protection degree
: 230 Vac 50-60Hz 900W (4A) max.
: 230 Vac 50-60 Hz
100W Resistive Load max.
50W Inductive Load max.
: 230 Vac 50-60Hz 750 W max.
: 12 Vdc 2,7A/h max.
: 12 Vdc 2 W max.
: 12 Vdc
: 10 ÷ 55 °C
: see model
: 12-18 Bit or Rolling Code
: 120 (CODE or CODE ALARM)
: 140x145 mm.
: 240x190x110 mm.
: IP 56
CONNECTIONS OF TERMINAL BOARDS:
CN1 :
1 : 230 Vac input (phase).
2 : 230 Vac input (Neutral).
3 : 230 Vac flash input (Neutral).
4 : 230 Vac flash input (phase).
5 : Opening 230V motor output.
6 : Common 230V motor output.
7 : Closing 230V motor output.
CN2:
1 : Power supply/ Battery charger Alarm signal + 13,8V.
2 : Alarm Control Output (positiv to miss).
3 : Power supply/ Battery charger Alarm signal GND.
CN3:
1 : Positive buffer battery input (+ 12V 2,7Ah max).
2 : Negative buffer battery input (- 12V 2,7Ah max).
3 : Signal light output (+ 12V 2W max).
4 : Signal light output (- 12V 2W max).
5 : AUX control contact output (NC) 30V 1A max.
6 : AUX control contact output (NC) 30V 1A max.
CN4:
1 : Power supply Photocells and Alarm sensors (+ 12V 5W).
2 : Power supply Photocells and Alarm sensors (GND).
3 : Input (Z2) Alarm zone 2 (NC).
4 : Input (Z1) Alarm zone 1 (NC).
5 : Common GND input.
6 : Input (DS) Safety motor Device (NC).
7 : Input (T) Tamper Alarm (NC).
8 : Common GND input.
9 : Input (P) Motor control Button (NA)
10 : Ground Antenna input.
11 : Hot pole Antenna input.

OPERATING FEATURES:

Using both the memorized radio-control (led CODE on) and
the Button (P) with low tension for the operation of doors
and windows, You will get the following operation:
The firs input rules the opening till the end of motor time or
till the Achievement of opening final run; the second input
rules the closure. If you send an input during the opening,
before the end of motor time Or the final run achievement,
or if you send an input during the Closing, before the end
of motor time or the final run achievement, The electronic
unit will do the reversal operation. Another input with sta-
tionary doors or windows always represents A restart of
the reversal operation.
Automatic closing:
The control unit closes the frame automatically without
sending other Commands. The choice of this operating
mode is described under The instruction for setting the
delay period.
9
Tabla de contenido
loading

Este manual también es adecuado para:

Lrx 2035 setLrh 2035

Tabla de contenido