ELECTRONIC PANEL LRX 2035 ALARM
GB
Control panel that integrates electronic control for
single-phase motor 230 Vac and Alarm System for the
supervision of 2 wired zones.
The control panel, equipped with intergrated battery
charger and radio receiver, is ideal for automation and
safety of garage doors, over head doors and rolling
shutters.
The control panel can be used in a combine manner, so
that the management of automation and alarm system
is reported to a single command, or so that a separate
control for automation alone and a control for the alarm
system alone.
- Mod. LRS 2035 Alarm
- Mod. LRS 2035 SET Alarm : 433,92 Mhz
- Mod. LRH 2035 Alarm
IMPORTANT FOR THE USER
- The device can be used by up to 8-year-old children or
persons with reduced physical-psychological abilities
or with little knowledge and experience, only if they
are supervised or trained on the functioning and the
use modalities in a safe way, to better know also the
dangers during its use.
- This instructions are available also on the website
www.seav.com.
- Do not allow children to play with the device and keep
the radio-controls away from their reach.
- Frequently examine the plant to detect any signs of
damaging. Do not use the device if a repair interven-
tion is necessary.
- Always remember toremove the power source before
polish or maintenace works.
- Polish and maintenance works must not be done by
children without any supervision.
ATTENTION: keep this instruction manual and respect
the important safety prescriptions contained herein.
The not compliance with the prescriptions may cause
damages and serious accidents.
: 433,92 Mhz
"narrow band"
: 868,3 Mhz
"narrow band"
IMPORTANT FOR THE INSTALLER
1) Before automating the frame, check that it is in
good conditions, in compliance with the Machinery
Directive and with EN 12604.
2) Control that place, where the installation is situat-
ed, respects the Temperature working limits, fixed
for the device.
3) The safety for the final installation and the respect
of all the rules (EN 12453 – EN 12445) are under
responsability of the person, who Assembly all the
parts together for building a closing.
4) Use safety disposals which can control their connec-
tion to the Electric panel.
5) To be sure of having done a right installation, you
should do a coplete check-up (progra-mation of the
electric unit and correct installation of safety dis-
posals).
6) In the back side, the shell is equipped with wall
fastening set up (holes for fastening by dowels or
screws). Consider and implement all Efforts for an
installation that does not change the IP degree.
7) The control unit does not have any type of isolating
device for the 230 Vac line. It will therefore be the
responsibility of the installer to Arrange an isolating
device inside the plant. It is necessary to install A
monophase switch with over-voltage category III.
It must be Positioned where it can protected from
accidental closing, according To that prescribed in
point 5.2.9. of EN 12453.
8) For what concerning cables for power, you should
use flexible Cables under policloroprene insulating
sheath of harmonized type (H05RN-F) with 1mm²
minimum size of conductor wires.
9) The gearmotor used to move the frame must comply
with that prescribed at point 5.2.7 of EN 12453.
10) In compliance with 5.4.2 of EN 12453, it is recom-
mended to use gearmotors equipped with an elec-
tric-mechanical release device, so that the door can
be moved manually in case of necessity.
11) In compliance with 5.4.3 of EN 12453, use electric-
mechanical release systems or similar devices
which stop the door safely in the end run position.
12) Wiring of the various electrical components outside
of the control unit must be carried out in compliance
with that prescribed in Standard EN 60204-1 and its
amendments at point 5.2.7 of EN 12453. Cables for
power can have a 14 mm Maximum diameter size.
Power supply and connection cables must be fixed
using the cable "optional" provided. Please Be
8