Available Temperatures with an Internal Controller
The water heater can deliver water at only one temperature setting at a time. The available temperatures are provided
below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the "On/Off" button on the
controller for 5 seconds while the water heater is OFF.
Fahrenheit °F 98 100 102 104 106 108 110 115 120 125
Celsius °C
37
* These models have a default maximum temperature of 120° F (49° C) and an option to increase the maximum temperature to 140 °F (60 °C).
Refer to section "3.12 Parameter Settings" for further details.
** These settings require the installation of the MCC-91-2 controller. When the MCC-91-2 controller is connected, these higher temperatures
are available on all controller models in the system. Use of an MCC-91-2 controller in a residential dwelling will reduce the warranty coverage
to that of a commercial warranty application.

4.4 Performance Data

To Obtain Performance Data:
1. Press and hold the
2. While holding the
press and hold the "On/Off" button (hold both buttons
simultaneously).
1
3. Use the
(Up) and
desired information described in the Performance
Data Table.
4. To exit performance data, repeat step 2 above.
5. When complete, the set temperature appears in the
display.
58
38
39
40
41
42
(Down) button.
(Down) button for 2 seconds,
2
(Down) buttons to scroll to the
Temperature Settings
*
43
46
49
52
Performance Data Table
Performance Data Table
#
#
DATA
DATA
0 1
0 1
Water Flow Rate
Water Flow Rate
02
02
Outgoing Temperature
Outgoing Temperature
03
03
Combustion Hours
Combustion Hours
04
04
Combustion Cycles
Combustion Cycles
05
05
Fan Frequency
Fan Frequency
06
06
Additional Controllers Connected *
Additional Controllers Connected *
07
07
Water Flow Control Position
Water Flow Control Position
08
08
Inlet Temperature
Inlet Temperature
09
09
Fan Current
Fan Current
1 0
1 0
Total Bath Fill Amount
Total Bath Fill Amount
1 1
1 1
HEX Outlet Temperature
HEX Outlet Temperature
12
12
By-Pass Flow Control Position
By-Pass Flow Control Position
Freeze Protection Temperature
Freeze Protection Temperature
15
15
(Indoor Unit Only)
(Indoor Units Only)
Freeze Protection Temperature
Freeze Protection Temperature
17
17
(Outdoor Unit Only)
(Outdoor Units Only)
19
19
Pump Hours
Pump Hours
20
20
Pump Cycles
Pump Cycles
2 1
2 1
Exhaust Temperature
Exhaust Temperature
* Refer to the Technical Data Sheet located on the inside
* Refer to the Technical Data Sheet located on the inside
front cover of the water heater for additional information.
front cover of the water heater for additional information.
Rinnai Tankless Water Heater Installation and Operation Manual
130
135
140
150
*
*
*
**
54
57
60
66
160
185
**
**
71
85
UNIT
UNIT
x0.1 gal/min
x0.1 gal/min
°F
°F
x100 Hours
x100 Hours
*
*
Hz
Hz
0=mid, 1=Open,
0=mid, 1=Open,
2=Closed
2=Closed
°F
°F
x10 mA
x10 mA
gallons
Gallons
°F
°F
Degrees of opening
Degrees of opening
°F
°F
°F
°F
x100 Hours
x100 Hours
*
*
°F
°F