Technical Specifications - De Dietrich 56254 Guia De Inicio Rapido

Termostato programación digital
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Auto Manu
1
2
3
4
5
6
+
°c
°c
-
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
DAYS
PROG
OK
1-7
P1-P4
Press the
button several times to obtain
6h00:the time to the wall displayed advances by 30
minutes for each short press. Continuous pressing
accelerates the time run-off.
- Press the
button several times to obtain
8h00.
- Press the
button several times to obtain
12h00.
- Press the
button several times to obtain
14h00.
- Press the
button several times to obtain
18h00.
- Press the
button several times to obtain
22h00.
Nota: If you make a mistake (e.g. 11:30 instead of
12:00) use the + and – buttons to advance or return
and correct with the
and
tons.
Press the OK, button.The following day automati-
cally appears.
Press the MODE to return to automatic mode.
Program reading
You can check your programming.
Auto Manu
1
2
3
4
5
6
+
°c
°c
-
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
DAYS
PROG
OK
1-7
P1-P4
From AUTO mode press the PROG P1-P4
button.
With the DAYS1-7 button select the day from 1
to 7 and check your programming on the 24-hour
profile at the bottom of the display panel (see
example above).
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Press MODE to return to automatic mode.
AUTO automatic mode
You pass into automatic mode by pres-
sing the MODE button until the pointer
L
appears under AUTO.
In automatic mode Thermostat adapts to
your life style by running the programs
you have selected.
MANU manual mode
Manual mode transforms your device into a simple
thermostat. It allows you to maintain a constant tem-
perature in your dwelling (set to a temperature of
between 5°C and 30°C).
Auto Manu
Auto Manu
+
°c
°c
-
Press the MODE button to position the pointer
L
under MANU.
Press + or – to adjust to the desired temperature
(for instance 22.5°C).To quit the MANU mode,
press MODE and re-position the pointer
AUTO.
Temporary temperature
7
modification
MODE
MODE
In automatic mode this
very useful function allows
you to modify ambient
temperature temporarily.
- To increase the temperatu-
Res
re, press the + button
(several times, if necessary).
- To decrease the temperature press the – button
(several times, if necessary).
The current temperature level indicator (comfort or
reduced) will begin flashing.
This modification ends with the next change in
programmed temperature.
To return to the initial program press MODE and
re-position the pointer
The current temperature level indicator (comfort or
reduced) will stop flashing when the temporary
modification comes to an end.
Prolonged absence mode
(holidays)
This mode protects your dwelling from freezing by
maintaining a minimum adjustable temperature in
thermometer but-
your dwelling during your absences (from 1 to 99
days).You can program the length of your absence so
that the temperature rises for your return.
Auto Manu
+
°c
-
0
1
DAYS
1-7
7
Press the
MODE
MODE
Set the length of your absence in days (from 1 to 99
days) with the + and –, the current day counts as
one.
0000
Validate with the OK button.
h
Res
Set the desired temperature level during your
absence with the + and – buttons.
Validate with the OK button.Remain in this mode.
To cancel and return to automatic mode, press
MODE.
Installer's guide
The programmable thermostat must be installed to an
inner wall about 1.50 m up from floor level, away from
direct sunlight and any source of heat, such as:TV set,
lighting, draught, etc.
MODE
MODE
Auto Manu
°c
Pull cover down and remove the screw.
Remove front face by unplugging it gently from the
base.
MODE
°c
MODE
L
under
Auto Manu
+
°c
°c
-
0
1
L
under AUTO.
1
2
3
4
5
6
7
days
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
PROG
OK
P1-P4
Res
button.
4
Fix the base on the wall.
2
3
4
5
Connect the thermostat following the picture
below.
1
2
Terminal N°1 - Output heating
If your boiler is equipped with a thermostat input,
remove the bypass of 2 thermostat terminals and
connect them respectively to terminals 1 and 3 of
the thermostat, to the 2 boiler's thermostat inputs
MODE
(any connection scheme will do).
Possible settings
Circulation pump anti-lock system
(starts the pump for 1 min every 24hrs).
I
Anti-locking
function off

Technical specifications

Adjustment range for comfort T°C: + 5°C to+ 30°C
Adjustment range for reduced T°C: + 5°C to + 30°C
Adjustment range for holiday T°C: + 5°C to + 30°C
Adjustment range for ambient T°C: + 0°C to + 40°C
Static differential:
Power:
2 standard LR6 alkalines batteries
Breaking power change over contact- 1 RT - 8 (3) A/250 V AC
Operating temperature:
Storage temperature:
Hygrometry:
Degree of protection:
Insulation class:
Connection:
by screwed barrier up to 2.5 mm
3
I
Anti-locking
function on
< 0,3 degrees
0°C to + 50°C
– 10°C to + 65°C
85 % max to + 20°C
IP 30
II (EN 60730 standards)
2
Tabla de contenido
loading

Tabla de contenido