Installation
Multiple Device Protection:
Note: The maximum distance between any two In-Line HDBaseT & 10G Network
Surge Protectors is 328 ft. (100 m).
1. Disconnect the installed patch cables from both of the devices you wish to
protect.
2. Connect an In-Line HDBaseT & 10G Network Surge Protector to each end
of the previously uninstalled patch cable, ensuring both ends of the patch
cable are connected to the "Cable End" of the In-Line HDBaseT & 10G
Network Surge Protector.
3. Using Cat5/5e/6 patch cables (not included), connect the "Equipment
End" of each In-Line HDBaseT & 10G Network Surge Protector to the
network devices you wish to protect.
Note: For best protection performance, the Cat5/5e/6 patch cable between the
"Equipment End" of the In-Line HDBaseT & 10G Network Surge Protector and the
network equipment to be protected should not exceed 300 ft. (90 m). Tripp Lite's
N001-Series Cat5e Snagless Patch Cables are recommended.
4. Connect the ground wire to each In-Line HDBaseT & 10G Network Surge
Protector and then to earth ground.