1. FEATURES
•
3 Mic inputs, 2 Aux inputs and 1 Aux output for link.
•
Speaker general outputs with line transformer 100V, 70V, & 8 Ω.
•
Zones outputs with line transformer 100V.
•
Muting function. MIC1 overrides other audio inputs.
•
Individual Volume control.
•
Low and High Tone control.
•
Vu-meter provided for a quick and easy monitoring of the sound level.
•
Short-circuit protection.
•
Individual distributor for 6 channels.
2. PRECAUTIONS
•
Do not block ventilation holes.
•
The amplifier should not be placed in areas:
-
with poor ventilation.
-
exposed to direct sunlight.
-
with high ambient temperatures.
-
adjacent to heat/generating equipments.
-
with high humidity or dust levels.
-
susceptible to vibrations.
•
Make sure the power outlet conforms to the plug of the unit.
•
Do not use this unit if the electrical power cord is frayed or broken.
•
Always operate the unit with AC ground wire connected to the electrical system ground.
3. MUTE FUNCTION
This amplifier provides Muting function. MIC2, MIC3, AUX1 and AUX2 are automatically muted by
MIC1 input (signal from MIC1 overrides the other input signals). The attenuation level can be
adjusted from 0 to -30 dB by adjusting MUTE control (10) placed on the rear panel. The factory
setting is -30 dB.
A-5240Z6N Version 1.0
A-5240Z6N
6 zones amplifier
Page 1 of 4