The mounting opening of the control unit points to the front. The control box is
mounted movably at the top and can be swiveled forward if required. To do
this, loosen the (lower fastening screws of the motor control box) on the right
and left using a three-way Allen key (not included in the scope of delivery).
Mounting
For the Ultra VA / 800, the electrical connection must be made in accordance
with installation instructions 47-21-0.
For the Ultra 500.i / Ultra 800i, the electrical connection must be made in ac-
cordance with installation instructions 47-21-i.
19.3. Test run with motor control 47-21-0
Push the gate manually to the "center" position and lock the gate (using the
emergency release).
Press the pulse button on the motor control board and let the gate run by me-
ans of the drive. Check the end positions. You can adjust the end positions by
moving the permanent magnets.
In the first two test runs of the gate, the running time and the power require-
ment are automatically stored. The running time determines the smooth run-
ning of the gate, the force requirement determines the amp stop.
28