TOF/Spot-Safety
Figure 3:
Horizontal safeguarding with the TOF/Spot-S
Inclined
Figure 4:
Inclined safeguarding with the TOF/Spot-S
Vertical
Figure 5:
Vertical safeguarding with the TOF/Spot-S
•
In the examples (Figure 3 to Figure 5) the sensor
recognizes the background. A background is needed
to successfully test the sensor with the test input. If the
TOF/Spot-S doesn't recognize a background within the
maximal range, the output will be switched to OBJECT
DETECTED.
•
The sensor looks towards a flat, plain background
(non-mirroring, remission between 2 ... 90%). There is
no need to be perpendicular to the optical axis.
© CEDES | V 4.0
Horizontal
TOF/Spot-S
Safeguarded
area
Background
TOF/Spot-S
Safeguarded
area
Background
4.6
Delivery package
A delivery package contains:
•
1 × TOF/Spot-S sensor with pigtail
•
1 × connection cable (2 m)
•
1 × quick guide manual (depends on the type ordered)
Figure 6:
TOF/Spot-S delivery package
4.7
TOF/Spot-S product overview
4
1
2
3
5
Figure 7:
TOF/Spot-S overview
1. Snap-in housing
2. Optical window
3. Status LED
4. Connection cable with pigtail
5. Potentiometer
6. Teach-in button and cap
English
6
5