PUMP PRIMING AND STARTUP
IMPORTANT: If the pump fails to prime within five minutes:
7. Turn the power off at the break box. Check all pipe connections for leaks, making sure all
connections are water and air tight. Check the inlet pipe for any sagging, making sure the inlet pipe
is in a straight line to the pump. Watch for leaks or a milky color in the discharged water, which
indicated an air leak. Re-prime if necessary, following steps 1 through 6. Reset breaker at the
breaker box.
IMPORTANT: If the pump hums instead of pumping or turns off repeatedly, shut pump off
immediately. Check voltage. Pump is wired to run on 230 volts. If the pump cuts out or stops, you may
be attempting to connect to 115 volts. See PUMP ELECTRICAL INSTRUCTIONS Page 17 to see how
to correctly change the motor voltage to 115 volts.
SPECIFICATIONS
Model
HSP10P1
HSP15P1
HSP20P1
MOTOR DATA CHART - HSP SERIES
HP
Phase
1
1-1/2
2
Suction
HP
Lift (FT)
15
10
3420
15
2820
1
20
2640
25
1440
10
4092
15
3780
1-1/2
20
3366
25
2520
10
4309
15
3894
2
20
3557
25
2640
Code
Volts
Letter
1
115
H
1
230
1
115
G
1
230
1
115
G
1
230
PERFORMANCE
Capacity - U.S. Gallons per Hour
Discharge Pressure (PSI)
20
25
30
3120
2700
2100
2640
2220
1800
2520
2160
1500
1380
1320
1020
3894
3564
3168
3660
3420
2970
3300
2838
2640
2490
2430
2280
4172
4036
3625
3780
3600
3300
3488
3420
3215
2599
2531
2430
20
Locked
Max
Rotor
Amps
Amps
17.6
62.0
8.8
31.0
18.00
72.0
9.00
36.0
21.00
108.0
10.50
54.0
Suction
Pipe
35
40
1200
0
600
0
2"
480
0
300
0
2508
1716
2310
1188
2"
1848
600
1452
0
3078
2462
2772
2112
2"
2531
1573
2220
720
Discharge
Pipe
1-1/2"
1-1/2"
1-1/2"