STAR Water Systems 40EC Guía De Referencia Rápida

Bomba para aguas servidas
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

SEWAGE PUMP
MODEL 40EC, 451558, S1267
QUICK REFERENCE GUIDE.
SEE INSTRUCTION MANUAL FOR
COMPLETE DETAILS.
Toll Free Help Line
1-800-742-5044
Your septic system is not a trash can! Do not pump:
Excessive chlorine or bleach
"Flushable" wipes
Salt brines
Paper towels
Latex or oil paint & thinners
Dental floss
Herbicides & pesticides
Feminine hygiene products
Oils & body lotions
Hair
Septic tank "enhancers"
Rubber gloves
Caustic drain openers
Condoms
Motor oil
Cat litter
3
Secure power cord to discharge pipe and plug into a GFCI-protected
outlet.
© 2020. All rights reserved.
1
Place pump securely in minimum 18 in. x 30 in. basin on a solid
surface such as a cement block.
Excessive kitchen grease
Egg shells
Fruit & vegetable peels
Cement
Coffee filters & grounds
Block
Seeds
Cooking oil
Onion skins
Sink-ground garbage
4
Add water to basin to test operation. Pump should turn on and off at
these approximate levels.
GFCI-
protected
receptacle
Model
40EC
S1267
30 in.
18 in.
Off
On Level
Level
12-1/2"
4-1/2"
12"
4"
2
Drill a 3/16 in. hole in the discharge pipe, level with the top of pump.
Pumps have a vent located in the pump, but an additional vent hole
is recommeded.Connect 2 in. discharge pipe with vent hole, union,
check valve and gate valve to main waste line.
Main
Waste Line
Check
Valve
Vent hole
located in
the pump
housing
5
Seal basin with lid and install vent pipe per codes.
Vent
Pipe
Gate Valve
Union
Additional
3/16-in.
Vent Hole
SW1620 A
loading

Resumen de contenidos para STAR Water Systems 40EC

  • Página 1 Place pump securely in minimum 18 in. x 30 in. basin on a solid Drill a 3/16 in. hole in the discharge pipe, level with the top of pump. MODEL 40EC, 451558, S1267 surface such as a cement block. Pumps have a vent located in the pump, but an additional vent hole is recommeded.Connect 2 in.
  • Página 2 SERVIDAS 45,72 cm (18 in.) x 76,20 cm (30 in.) sobre una superficie sólida, Perfore un agujero de como un bloque de cemento. MODELO 40EC, 451558, S1267 5 mm (3/16 pulg.) de Válvula de Tubería de diámetro en la tubería GUÍA DE REFERENCIA RÁPIDA.

Este manual también es adecuado para:

451558S1267