TESTING THE BATTERY

After fully charging the battery so all red lights come on, apply a 100 amp load to
the jump starter, for a period of 6 seconds, while monitoring the battery voltage.
The battery is good if the voltage is 9.5 VDC or higher.
BATTERY REMOVAL AND DISPOSAL INSTRUCTIONS
Pb
The battery inside this product is a sealed lead-acid battery. It is required by law to
be removed and recycled or disposed of properly. When the battery in this product is
in need of replacement, remove it according to the instructions provided below and
take it to your local recycling center for proper recycling or disposal. If you don't have
Pb
Pb
a local recycling center that handles sealed lead-acid batteries, contact your local
environmental agency for instructions.
Removal Instructions
Begin by making sure that both clamps are securely stowed in their holsters on each
side of the jump starter.
1. Lay the jump starter down on its front. Locate the 13 screws that hold the case
together (four on the left edge, four on the right edge, four along the bottom
and one under the front label).
2. Remove the 13 screws, then lift off the back half of the case.
3. On the top of each battery are two terminals, each with wires connected
to them. Disconnect these wires from the top battery first, by removing the
bolts that hold them to the battery terminals. Disconnect these wires from the
bottom battery by removing the bolts that hold them to the battery terminals.
To prevent accidental arcing, be careful not to touch both battery terminals
with the tools being used to remove the bolts.
4. Lift the batteries out of the front half of the case.
CONTAINS SEALED LEAD-ACID BATTERY.
BATTERY MUST BE RECYCLED.