6.1
Troubleshooting table
/i
Fault
Cause
The heater is not
1
The heater has no voltage.
functioning.
2
Defect in the operating
panel.
3
Phase - exchange the ZERO
wires in a 5-pole connector/
female connector.
4
Internal fuse (2A) faulty.
(VTB 9000/15000/18000)
The fan does not turn
5
The thermostat is set to a
and there is no heat.
too low temperature.
6
Fuse is faulty in your sys-
tem.
7
Fan motor is broken.
The fan does not turn
8
Fuse is faulty in your sys-
but the heater does
tem.
heat up.
9
Fan faulty
The fan does turn but
10 Voltage too low
the heater does not
emit heat.
11
One fuse is faulty in your
system.
12 Cable of the extension cable
faulty. Heater functions on 2
phases.
The fan turns as nor-
13 One fuse is faulty in your
mal but there is little
system.
heat, 50%.
14 Cable of the extension cable
faulty.
15 Heater functions on 2
phases.
16 One loose or burnt cable in
the connector/female con-
nector or extension cable.
Record the maintenance details in table A in
1
6
4
0
0 .
2
0
9 .
16
40.020.939 - rev. 06 - 2016
Solution
Action
Check the electrical con-
User
nection.
Repair or replace the
Dealer
operating panel.
Repair the connection.
User
Replace the fuse.
Dealer
Correct the settings.
User
Replace the fuse. (Make
User
sure it is tight.)
Replace the fan motor.
Dealer
Replace the fuse. (Make
User
sure it is tight.)
Replace the fan motor.
Dealer
Check the electrical con-
Dealer
nections.
Replace the fuse. (Make
User
sure it is tight.)
Repair the connection of
User
the system.
Replace the fuse. (Make
User
sure it is tight.)
Repair the connection.
User
Repair the connection.
User
Repair the connection.
User
the annex at the back of this manual.
3
9
-
e r
. v
0
4
-
2
0
1 1
V
T
B
3
0
0
0
9 /
0
7
Contact the dealer for the use of spare parts.
8
•
For technical specifications, see table B
in the annex at the back of this manual.
•
For the electrical circuit diagram, refer to
diagram C in the annex at the back of this
manual.
8.1
/i
Pos.
C
CL
M
Th
Ac
F
Tr
9
9.1
An air hose may be connected to the outlet
opening of the heater in order to blow hot air
at a large distance from the heater.
Contact your dealer for information about the
maximum length of the outlet hoses, bends,
manifolds and hose clamps.
10
For the EC declaration of conformity, go to
www.thermobile.nl.
0
0
1 /
5
0
0
0
VTB 3000/9000/15000
VTB
VTB
SPARE PARTS
TECHNICAL INFORMATION
Explanation of the electrical circuit
diagram
Description
Condenser
Maximum thermostat
Motor
Thermostat
After-cooling
Internal fuse
Transformer