Blue Angel Pumps BWLS Serie Instrucciones De Operacion Y Lista De Partes

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Operating Instructions and Parts Manual
Description
This pump is a high capacity, self-prim-
ing centrifugal pump suitable for lawn
sprinkling or other applications where
large quantities of water are required.
Flammable liquids such as gasoline,
chemicals or corrosive liquids should
never be used with this pump.
Safety Guidelines
This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important infor-
mation, that if not followed, may cause
damage to equipment.
General Safety Information
1. Read these rules and
instructions carefully.
Failure to follow these
instuctions could
cause serious bodily
injury and/or property damage.
© 2007 Blue Angel™ Pumps
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure
to comply with instructions could result in personal injury and/or property damage! Retain instructions
for future reference.
Lawn Sprinkler
Pump
Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil,
kerosene, etc. Do not use in a flamma-
ble and/or explosive atmosphere.
Personal injury and/or property dam-
age could result.
salt water, brine, laundry discharge or
any other application which may con-
tain caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will
void warranty.
All wiring must be per-
formed by a qualified
electrician. The pump
must be installed in com-
pliance with all local and national
codes.
2. Connect this product to a grounded
circuit equipped with a ground
fault interruptor device.
3. Before installing this product, have
the electrical circuit checked by an
electrican to ensure proper ground-
ing.
4. BE CERTAIN the pump
power source is dis-
connected before
installing or servicing
pump.
5. Check motor voltage setting on
motor endplate and make sure the
line voltage of the electrical current
supply is correct.
6. Be sure the water source and piping
is clear of sand, dirt and scale.
For parts, product & service information
visit www.blueangelpumps.com
This pump is non-
Debris will clog pump and void war-
submersible.
ranty.
7. Failure to protect pump and piping
from freezing could cause severe
damage and will void the warranty.
8. Do not run pump dry. Follow prim-
ing instructions.
Installation
This pump is not
Protect pump from the elements by
designed to handle
installing in a basement, garage, tool
shed or pump house. Install the pump so
the centerline of the pump is as close as
possible to the water level. Keep installa-
tion area clear to provide access for ser-
vice and maintenance. Protect the pump
against flooding and excess moisture.
Make sure the pump has adequate ven-
tilation. The surrounding temperature
should not exceed 100
sance tripping of the motor may occur.
PUMP PIPING INSTALLATION
Use new pipe for best results.
Galvanized or plastic pipe can be used.
When using galvanized pipe, provide
independent supports for both suction
and discharge piping near the pump to
avoid strain on the pump. Minimize use
of elbows and fittings to reduce friction
loss. Refer to the friction loss chart for
specific information.
Increase diameter of suction or dis-
charge piping if length is over 50 feet.
SUCTION PIPING
over intake of suction piping.
Never use pipe smaller than 2" in
diameter for suction piping. The suc-
tion pipe must be kept free of air leaks.
BWLS Series
o
F (38
o
C) or nui-
Install foot valve
or strainer screen
320200-002 1/07
Tabla de contenido
loading

Resumen de contenidos para Blue Angel Pumps BWLS Serie

  • Página 7: Service Record État De Service Hoja De Servicio

    BWLS Series Operating Instructions and Parts Manual Série BWLS Instructions d’Utilisation et Manuel de Pièces de Rechange Serie BWLS Manual de Instrucciones y Lista de Repuestos Service Record État De Service Hoja de Servicio Lawn Sprinkler Pump Pompe Pour Arrosoir De Pelouse Bomba Para Regar Césped Date Maintenance performed...
  • Página 8 BWLS Series Operating Instructions and Parts Manual Série BWLS Instructions d’Utilisation et Manuel de Pièces de Rechange Serie BWLS Manual de Instrucciones y Lista de Repuestos Notes Notas www.blueangelpumps.com...
  • Página 15: Bomba Para Regar Césped

    Serie BWLS Manual de Instrucciones y Lista de Repuestos Sírvase leer y guardar estas instrucciones. Lea con cuidado antes de tratar de armar, instalar, manejar o darle servicio al producto descrito en este manual. Protéjase Ud. y a los demás observando todas las reglas de seguridad.
  • Página 16: Conexion A La Fuente De Agua

    Manual de Instrucciones y Lista de Repuestos Bomba para Regar Césped Instalación (Continuación) Hacia la Bomba Hacia la bomba Si la longitud de las tuberías es más de 15,2 metros (50’) debe aumentar el Sello del pozo diámetro de las tuberías de descarga. TUBERIAS DE SUCCION Instálele válvula de pie o un colador en la entra-...
  • Página 17: Tabla De Alambrado - Alambres Y Fusibles Recomendados

    Manual de Instrucciones y Lista de Repuestos Serie BWLS modelo BWLS200 no se puede modi- Instalación (Continuación) tubería de succión sea suficientemente ficar; esta bomba sólo funciona con larga para que siempre permanezca llenen de agua durante el proceso de sumergida.
  • Página 18: Mantenimiento

    Manual de Instrucciones y Lista de Repuestos Bomba para Regar Césped agua limpia. Encienda la bomba. Si la 3. Cerciórese de que la(s) válvula(s) de contra temperaturas congelantes. Si las tuberías de descarga o de suc- hay peligro de que se congelen, drene ción estén abiertas (de haberlas).
  • Página 19: Diagnóstico De Averías

    Manual de Instrucciones y Lista de Repuestos Serie BWLS Diagnóstico de Averías Problema Posible(s) Causa(s) Acción a Tomar El motor no funciona 1. El interruptor está en “off” 1. Cerciórese de que el interruptor esté en “ON” (encendido) (apagado) 2. El fusible está quemado 2.
  • Página 20 Manual de Instrucciones y Lista de Repuestos Para ordenar repuestos comuníquese con el distribuidor más cercano a su domicilio Sírvase suministrarnos la siguiente Puede escribirnos a: Blue Angel™ información: -Número del modelo 101 Production Drive Harrison, OH 45030 U.S.A. -Número de Serie (de haberlo) -Descripción y número del repuesto según la lista de repuestos No.

Tabla de contenido