Before Starting Up - Forch 5352 2200 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
11. Delivery
1× Angle Grinder 125 mm
1× Plug nipple (Art. no. 3926 14 3)
2× Open-end wrench 14 mm
1× Allen Key

12. Before starting up

IMPORTANT:
The use of air filters and a compressed air hose lubricator is recommended.
ATTENTION!
Before lubricating, connecting or disconnecting of the tool disconnect the compressed air.
Lubricating the tool, see maintenance in this operation manual.
Remove the dust cap at the compressed air inlet.
Connect the unit to a hose of suitable size.
13. Starting up
Switch on the compressor for the air tank to be filled.
Put the compressor regulator to approx. 90 PSI or 6.3 bar. The max. operational
pressure of this device is at approx. 90 PSI or 6.3 bar.
The turning capacity might vary depending on the size of the compressor and the
volume of the compressed air output.
Do not use damaged, worn or sub-standard air hoses or connectors.
The pressure control for achieving the right tool speed is done by means of the compres-
sor regulator resp. a pressure regulator to be mounted additionally.
The speed regulation is done via an air inlet regulator (not contained in the delivery).
The technical data of this tool is based on operation at 6.3 bar pressure.
Always be careful when using this cutter. When using the device carelessly the inner
parts resp. the housing could be damaged and the operational performance reduced.
Press the lever for actuating the tool.
Release the lever to stop.
Note that the tool keeps running even after release of the lever.
Switch of the compressor and store it according to the operation manual after having
finished work.
Only use dry, clean air with approx. 90 PSI or 6.3 bar max. pressure. Dust, flammable
vapours and too high humidity can destroy the motor of a pneumatic device.
Do not remove labels, replace damaged labels.
Keep hands, loose clothing and long hair away from moving parts of the unit.
Place the cutting disk onto the flange and center well.
Screw on the clamping nut by hand and tighten with the open-end wrench. Hold with the
second open-end wrench.
Spark protection (protective hood) can be loosened and set as required with the en-
closed Allen Key.
The spark protection (protective cover) must not be removed for safety reasons
Check the air pressure and adjust if necessary until the correct operational pressure is
reached.