Electrical Specifications - Urmet 1071/32 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

It may be installed in the following switch ranges by
using the 1056/337 adapter kit: Bticino (Living Light,
Living International and Living), Vimar Idea and
Plana, Gewiss Playbus.
Remove the two fins (upper and lower)
from the devices to use the BTicino Living, Vimar
Plana or Vimar Idea adapter.
12
3. SPECIFICATIONS
3.1

Electrical specifications

• Bus powered: 0.5 UL
• Bus terminal configurable by means of jumper:
TERM
• Temperature range: 0 - 50 °C (32 - 122 °F)
• Default calibration factor (editable by IPerSet): -
2.5 °C (27.5 °F)
• Default hysteresis (editable by IperSet): 0.5 °C
(0.9 °F)
3.2
Logical features
• Configurable with IPerSet software, via USB (see
1071/56)
• 254 possible logical addresses
• Capable of controlling the pump/boiler relay and
one or more zone solenoid valves
• Front button can be deactivated
• Four reference temperatures: Comfort / Day /
Night / Safe (or Protection)
• Programmable timer (default: 1 hour)
• Two temperature alarm thresholds: low (lower
than the safe threshold) or high (higher than pro-
tection threshold), usable as events capable of
triggering an alarm
• Fan booster management
DS1071-012