4. Perform the test using the same steps described in Operation & Testing section
above to ensure the unit is working properly.
Trouble Shooting
Symptoms
Possible Cause
Device does not work,
No batteries attached or
LED does not illuminate.
no power.
LED does illuminate,
Binding with gateway did
appliance does not
not complete
respond
successfully.
Disturbed by other radio
waves

Reset to Factory Settings

To reset TSM04 back to factory default state:
1. Press and hold the Learning button for 3 seconds until the LED flashes
moderately then release the button.
2. Within 30 seconds, press and hold the Learning button again, this time for more
than 6 seconds then release the button.
3. Re-insert the batteries, if the LED blinks slowly for 30 seconds this implies the
device is reset back to factory mode.
Specifications
Operating temperature range
Operating humidity
Battery type
RF Frequency
Magnetic
RF transmission range
*Specifications are subject to change without notice.
Recommendation
Check if batteries are
attached or replace with
new ones.
Bind again using manual
binding
Please operate later
0°C to 40°C
85% RH at 30°C
AA alkaline 1.5V *1
868.30 MHz/923.00MHz
OPEN CLOSE >20mm
CLOSEOPEN <35mm
Outdoors >200m (Open space)
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact your local government for information regarding the collection systems
available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak
into the groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated to take back
your old appliance for disposal free of charge.
CAUTION:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE
OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
50 Sect. 1 Zhonghua Rd Tucheng
NewTaipeiCity 236 Taiwan
www.everspring.com
A501112666R