5
5. The following screen will appear. This means the gateway is entering binding mode.
6. At this point, insert the battery with correct polarity into the unit.
7. The screen below will appear within 10 seconds if the process is successful.
8. Time-out will occur if the binding process was unsuccessful. Please refer
to Manual Binding in the Troubleshooting section.
Installation
1. Mount the Magnetics Detector in dry interior locations only.
Note: Don't place the unit near combustible substances or any source of heat,
e.g. fires, radiators, boilers etc.
Note: Mounting the detector to a metal frame or within 1 meter of metalwork
(e.g. radiators, water pipes) may affect radio range of the device. Please use
plastic or wooden spacers to separate the detector and metal surface when
required.
2. Fit the magnet on the moving part of the door/window, and vice versa if
necessary. The magnet could be in the detector both side. Use the provided
self-adhesives tape to secure them in place.
3. Make sure the parallel gap between the magnet and detector is less than 20mm
and that they are aligned from the top. An alarm will be triggered if the gap is
greater than 35mm.