INSTALLATION INSTRUCTIONS
LED E-DD0L40 SERIES
FIGURE 4
ARM MOUNTING
Requires Use of Mounting Kit E-ACADD1
FIGURE 5: Arm Mounting Components
1.
Remove (2) hex bolts holding arm bracket to fixture.
Discard arm bracket (Arm bracket included with arm
mounting kit will be used)
2.
Loosely install (2) carriage bolts with lock washers and nuts
into wall mount bracket.
3.
Install wall mounting bracket to mounting surface with (4)
Lag bolts provided.
4.
Insert short end of arm into mounting bracket. Adjust to
desired direction and tighten carriage bolts.
5.
Feed (Customer Supplied) Ground wire up through arm.
6.
Feed black and white fixture wires down through arm.
7.
Using (2) Hex bolts included with fixture and arm bracket
supplied with the arm kit, secure housing to arm.
NOTE: When installing the housing on to the arm, allow
1/4" (6.4 mm) spacing between end of arm and the housing
to prevent ground wire from being pinched.
8.
Install (1) green ground screw onto arm bracket at location
marked "GND" and tighten ground screw to ground wire.
9.
Wire black fixture lead to the incoming voltage supply
or Hot 1 lead and the white fixture lead to the incoming
neutral (Common) or Hot 2 lead.
10. Install the photo-control by aligning the arrow on the top
of the photo-control with the arrow on the photo-control
socket and inserting pins into the socket. Twist photo-
control clockwise until the arrow on the photocontrol is
pointing north. (Photocontrol must be rotated at least 1/8
turn to properly lock in place). See Figure 6.
NOTE: Improper installation of the photo-control may result
in damage to the photo-control.
E-DD0L SERIES-
ARM MOUNTED
www.e-conolight.com
|
Document:
LPN00370X0001A0_A
Created By:
TMT
FIGURE 6- Photo-control Installation
CAUTION: Changes or modifications not expressly approved could
void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CAN ICES-005 (A)/NMB-005 (A)
888.243.9445
|
FAX: 262.504.5409
Date
ECO#
FCC NOTICE
2018-4-24
009113