Technical Data And Limitations Of Use; Management; Storage - Tallas Pumps P1-272W Instrucciones De Instalación Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. TECHNICAL DATA AND LIMITATIONS OF USE

Supply
voltage: 127V, see electrical data plate
Delayed line fuses

Storage

temperature: -10°C – 40°C
Electrical data
Hydraulic data
Range of use
Weight
Supply
voltage: 230V, see electrical data plate
Delayed line fuses
Storage
temperature: 14 F – 104 F
Electrical data
Hydraulic data
Range of use
Weight
The pump which does not stand on a base cannot support the weight of the pipes, which must be
supported in some other way.

4. MANAGEMENT

4.1
Storage
All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
(127V 60Hz version):
P1 Rated absorbed power [W]
P2 [W]
USA P2 [HP] Fractional (decimal)
Mains voltage [V]
Mains frequency [Hz]
Current [A]
Capacitor [µF]
Capacitor [Vc]
Max. flow rate [l/min]
Max. head [m]
Max. immersion depth [mm]
Min. AUT starting height [mm]
Min./max. stopping height [mm]
AUT residual water height [mm]
Type of cable
Grade of motor protection
Insulation class
Liquid temperature range [°C]
according to EN 60335-2-41 for domestic use
Max. particle dimension [mm]
Max. ambient temperature [°C]
DNM NPT
(230V 60Hz version):
P1 Rated absorbed power [W]
P2 [W]
USA P2 [HP] Fractional (decimal)
Mains voltage [V]
Mains frequency [Hz]
Current [A]
Capacitor [µF]
Capacitor [Vc]
Max. flow rate [gpm]
Max. head [ft]
Max. immersion depth [inch]
Min. AUT starting height [inch]
Min./max. stopping height [inch]
AUT residual water height [inch]
Type of cable
Grade of motor protection
Insulation class
Liquid temperature range [F]
according to EN 60335-2-41 for domestic use
Max. particle dimension [inch]
Max. ambient temperature [F]
DNM NPT
ENGLISH
indicative values (Ampere)
Model
Table 2a
indicative values (Ampere)
Model
Table 2b
2
Draining clear water
P1= 272 W
P1=611 W
272
611
168
263
0.2
0.4
~ 127V AC
60
2.2
5.3
10
20
450
250
107
186
6
8.8
7
115
45/115
2-3
SJTOW 18AWG
IP X8 / NEMA 6P
F
+0°C / +35°C
5
40°C
1'' 1/4 M
Draining clear water
P1= 280 W
P1=540 W
280
540
170
230
0.23
0.31
~ 230V AC
60
1.3
2.4
8
10
450
26.9
47.3
20.7
30.5
0.3
4.5
1.8/4.5
0.08-0.12
SJTOW 18AWG
IP X8 / NEMA 6P
F
+32 F / +95 F
0.2
104 F
1'' 1/4 M
Tabla de contenido
loading

Este manual también es adecuado para:

P1-611wP1-280wP1-540w

Tabla de contenido