TiEmme FC310 Manual De Uso página 5

Idiomas disponibles

Idiomas disponibles

FC310
L1
M
Type
Code
SONDA
Inputs
PROBE
VENT
Outputs
LINEA
LINE
Mechanical Dimensions: Inbox Controller: 120 x 80 x 50 mm
Absorbed Power: 2VA
Applied Rules:
EN 60730-1 50081-1 EN
60730-1 A1 50081-2
Tel: +39 075.8743.905 Fax: +39 075.8742239 [email protected]
1.
MAIN
The device allows to control the fan's speed connected
The speed is set by turning the knob M to 10 speed steps: U1, ...U9, U10
The Manual/Automatic modality is set using the button P1
The device allows to use 2 types of Temperature Probes:
Thermostat ON/OFF Normally Open contact
Probe with Temperature Sensor NTC100K.
In case the Probe or Thermostat is not used: make a bridge on the 5-6 pins
2.
ON / OFF
The Controller is turned ON and OFF by the button P2
The OFF state is signalled by led L4.
3.
FUNCTIONING Modalities
The activation of the fan is signalling by the led L1
AUTOMATIC Modality led AUT (L2) ON
The fan is activated at the set speed through the knob M if:
Input PROBE closed in case of used Probe is a THERMOSTAT or
If the read temperature is over the thermostat A01 in case of used Probe NTC100K
MANUAL Modality: led MAN (L3) ON
The fan works at the set speed through the knob M independently of the temperature read by the
Probe/Thermostat
4.
SAFETY Function
The device is supplied with the function disabled: Sic = 0
In case of the function is enabled Sic=1:
If the Controller is OFF (L4 ON) and the contact PROBE is closed or the read temperature by the
Probe NTC100K is over the thermostat A02
The Fan is forced at the speed U1
This condition is signalled by the blinking of the led L1
AUT
L2
L4
OFF
MAN
L3
P1
P2
Fig. 1 External aspect and electrical connections
Pins
5 – 6
3 – 4
FAN
1 – 2
LINE
To comply with CEI EN 55014, install an appropriately
sized EMI filter and a protection Fuse before the LINE
Input
TiEmme elettronica Marsciano (PG) Italia
User Manual
Device
Air Probe
Thermostat
Heating Fan
Power Supply
Pag. 5 / 8
SONDA
PROBE
6
5
1 2 3 4
LINEA
VENT
LINE
FAN
230 V ac
230 V ac
Characteristics
NTC100K@25°C
Contact Open/Closed
Main Power Voltage 230 Vac
230 Vac 10% 50 Hz
0CAR6IN019145
GB