WHITE-RODGERS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
This control has been especially designed for use on
refrigerated cabinets such as milk coolers and cold drink
dispensers where an ice bank is built up as a means of
storing refrigeration.
The purpose of the control is to start and stop the com-
pressor motor to maintain an ice bank of a desired
thickness.
THIS CONTROL MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to calibrate this control will void the White-
Rodgers warranty.
WARNING
!
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.
If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.
ELECTRICAL DATA
Switch Action: S.P.S.T.
Switch Rating: 14.0 F.L.A., 84.0 L.R.A. @ 120 VAC
7.0 F.L.A., 42.0 L.R.A. @ 240 VAC
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300, FAX (314) 577-1517
9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625
Ice Bank Control
INSTALLATION INSTRUCTIONS
When the thickness-sensitive bulb is completely covered
by ice, the internal hydraulic-fill of the bulb actuates the
switch, opening the contacts and stopping the compres-
sor.
As the ice bank starts to melt away, the internal hydraulic-
fill of the bulb again actuates the switch, closing the
contacts and starting the compressor.
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.
Following installation or replacement, follow
appliance manufacturers' recommended instal-
lation/service instructions to insure proper
operation.
THERMAL DATA
Range: Any desired thickness of ice bank.
Differential: Approx. 1/16" of desired thickness of ice
bank.
Printed in U.S.A.
16A35
DESCRIPTION
PRECAUTIONS
CAUTION
!
SPECIFICATIONS
PART NO. 37-1110C
Replaces 37-1110B
9722
Tabla de contenido
loading

Resumen de contenidos para White Rodgers 16A35

  • Página 5: Control Del Banco De Hielo

    INSTRUCCIONES DE INSTALACION Control del Banco de Hielo WHITE-RODGERS 16A35 Operador: ¡ Guarde estas instrucciones para usarlas en el futuró! SI NO SE LEEN Y SE SIGUEN TODAS LAS INSTRUCCIONES CUIDADOSA- MENTE ANTES DE INSTALAR U OPERAR ESTE CONTROL SE PUEDEN PRODUCIR LESIONES PERSONALES Y/O DAÑO A LA PROPIEDAD.
  • Página 6: Instalacion

    INSTALACION No hay ajustes de dial en este control. Sólo es necesario MONTAJE DE LA BOMBILLA: ubicar la bombilla correctamente. 1. El control viene equipado con dos amarras de cobre, El primer ciclo del equipo puede producir un banco de ajustables, para montar la bombilla en el evaporador.

Tabla de contenido