Installation (continued)
3
Connecting stranded copper
house wire
WARNING: Turn the power off at the circuit breaker or
fuse. Place tape over the circuit breaker switch and verify
power is off at the light fixture.
IMPORTANT: Use only NM-B 14/2 or 12/2 wire for the pigtail. The
pigtail wire size must match the existing house wiring (14 AWG or
12 AWG). Color match the solid-core wire and the house wire when
connecting together.
If the house wiring is stranded wire instead of solid-
core copper wire, a pigtail using solid-core wire (2) will
be required (not included). Follow these instructions
to connect the mounting plate (D) using the pigtail
method.
Cut 4 to 6 inches of NM-B wire (2) to match the
existing house wire (14 AWG or 12 AWG).
If necessary, strip 5/8 in. of insulation from
junction box wires (1).
Strip 5/8 in. of insulation from one end of the
solid-core wire (2).
Attach the two wires together using a wire
nut (3 - not included). Ensure the solid-core
wire insulation matches the junction box wire.
Repeat for the remaining two wires.
To attach the solid-core pigtail to the mounting
plate (D), strip 5/8 in. of insulation from the
other end of the solid-core wire. Use the wire
length measuring guide on the back of the
mounting plate (D) to ensure the correct wire
length.
Insert the pigtail wires into the side of the
terminal block on the back of the mounting
plate (D).
Insert the white pigtail wire into the
terminal marked "N".
Insert the black pigtail wire into the
terminal marked "L".
Insert the bare or green ground pigtail
wire into the terminal marked "G".