Accessories
UTC Fire & Security can provide a handheld walk tester DI601-
WT to aid installations.
Specifications
Detection range
Programmable: 10 m, 20 m or 30 m
Coverage
10 to 70° detection angle, 30 x 24 m
coverage max.
−45° to +45° pan, tilt +45°
Adjustment
Fresnel lens
28 zones for each detection element, which
can be masked with the curtain sliders
Customized optics
Double silicon shielded quad element
eliminates 50,000 lux of white light
LEDs
Top PCB
Red: Programming LED
Sensor PCB
Blue: Detector alarm
Red(small): Anti-mask alarm
Infrared: Walk tester communication
Outputs
Silent, solid state, magnetically immune
NO
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor
Alarm time 5 seconds
NC
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor
Alarm time 5 seconds
Fault/Mask
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor
Power input
10 to 15 VDC
Current
16 mA (12 V nominal)
Standby 27 mA MAX
Pulse count
1 or 2
Temperature
Analogue (thermistor) and digital sensitivity
compensation
adjustment
Control
Digital microprocessor with nonvolatile
memory
Walk test
Output test mode with LED indication.
Option to disable LEDs
−30 to +65°C
Operating temperature
Housing
High impact ABS plastic with HDPE cover,
UV stabilized
Dimensions, W x H x D
125 x 175 x 130 mm
Weight
365 g net, 551 g gross
Mounting height
Variable up to 6 m
Optimum height 3 m for full range
Regulatory information
Manufacturer
Placed on the market by:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 280923,
USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
P/N 146656999-1 (ML) • REV F • ISS 01MAR19
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
EN 50130
EN 50130-5
EN 50131
EN 50131-2-2, Grade 3, Class IV
Certified by Telefication B.V.
Note:
EN 50131-2-2 compliant only when
mounted at 1.5 and 3 m
Environmental
IP55
class
This product meets the environmental
requirements of EN 50130-5.
European Union
UTC Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.utcfireandsecurity.com or
www.interlogix.com.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/
Contact information
www.utcfireandsecurity.com or www.interlogix.com.
For customer support, see www.utcfssecurityproducts.eu.
DE: Montageanleitung
Verpackung
Diese Verpackung enthält folgendes:
1 x DI601AM
1 x Bohrschablone für Befestigungsbohrungen
3 x Wanddübel (31,75 mm)
3 x Schrauben (31,75 mm)
1 x Objektivabdeckung
2 x zusätzliche Schlitzverschlüsse
1 x Sabotagehalterung
2 x Sabotagekappen (unterschiedliche Längen)
1 x Fixierwerkzeug (Kunststoff)
1 x Montageanleitung
1 x Verschlusskappe für die Frontabdeckung
or scan the QR code.
7 / 46
Tabla de contenido
loading

Este manual también es adecuado para:

Ddi602am

Tabla de contenido