15
Ja
Ra
5
Alarm N/C
Rt
Tamper
7
J TEOL
Fault
4
Jf
Rf
Alarm N/O
9
22R
16
( ) 1
(2)
EN: Installation Sheet
Package
The package contains:
•
1 x DI601AM
•
1 x drilling template for fixing holes
•
3 x 31.75 mm wall plugs
•
3 x 31.75 mm screws
•
1 x lens mask
•
2 x additional curtain shutters
•
1 x tamper cup
•
2 x tamper caps (different lengths)
•
1 x plastic locking tool
•
1 x installation sheet
•
1 x front cover screw cap
Introduction
The DI601AM Outdoor PIR/AM Detector is an external motion
detector and alarm trigger that uses two independent passive
infrared detectors
Both sensors must trigger to cause the detector to signal an
alarm. The DI601AM uses quad PIR technology to deliver
precise, reliable presence detection.
Programmable options include a variable pulse count and a
choice of three detection ranges: 10 m, 20 m and 30 m.
P/N 146656999-1 (ML) • REV F • ISS 01MAR19
6
Jt
8
3
10
STANDBY
CURRENT
DI601AM+16mA
DDI602AM+22MA
0V
+12V
ALARM N/O
ALARM N/O
TAMPER
TAMPER
ALARM N/C
DEOL
ALARM N/C
TEOL
FAULT/AM
FAULT/AM
REMOTE TEST
REMOTE LED
17
Mounting the unit
When positioning the detector please consider that the PIR
sensor is more sensitive to a movement across the beams,
and less sensitive to a movement directly towards or away
from the beams; whilst the microwave sensor is more sensitive
to movement towards and away from the sensor.
During installation, protect the electronics against water, as
trapped moisture can affect or damage the unit.
We recommend that the cable entry and screw mounting holes
be sealed from within the detector using acrylic (non-silicone
based) sealants.
When locating the detector, please ensure the detector's
Note:
field of view is unobstructed.
To mount the detector:
1.
Drill the wall to accept the two fixing screws, the cable
entry, and the tamper cup (if used). See Figures 1 and 3.
A hole-drilling template is provided.
Notes
•
Leave a minimum 10 cm (4 inches) clearance above
the top of the detector housing to allow the cover and
the detector to be positioned correctly.
•
We recommend using the tamper cup on uneven wall
surfaces. See Figure 3.
15a
( ) 1
(2)
( ) 4
(1) (2) (3)
( ) 3
STANDBY
CURRENT
DI601AM+16mA
DDI602AM+22MA
3 / 46