FEATURES
Electronic basin tap:
• Pressure: 1 - 5 bar (100 - 500kPa), we recommend 3 bar (300kPa).
• Calculate pipe sizes in relation to the probable flow rates and dynamic pressure.
• The electrical installation must comply with local norms and regulations.
• To avoid interference with infrared rays do not install two electronic taps/mixers facing each other or a mirror,
or a bright object.
OPERATION OF ELECTRONIC VERSIONS
• Automatic open and closing when hands are in front. Comfort time flow is 3 seconds.
• Anti-blocking safety: a safety timer ensures shut-off after 30 seconds of flow, when the obstacle is removed,
the operation restarts automatically.
• Hygienic duty flush every 12 or 24 hours (or OFF) after the last use: (fig. S).
INSTALLATION
THE INSTALLER MUST ENSURE:
• THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION, RUN OFF, LEAKS,
ETC.) HAS AN EXTERNAL DRAINAGE POINT TO PREVENT ANY STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL OR
THE WALL PLATE AND THE TAP AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821. ALL OTHER
MARKETS: +33 (0)3 22 60 22 74.
REMEMBER
• Our taps must be installed by professional installers in accordance with current regulations and
recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the tap to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the tap several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: [email protected]
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: [email protected]
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN
14
Tabla de contenido
loading

Este manual también es adecuado para:

Nt 370kit

Tabla de contenido