RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The
transmitters are not erased from the receiver nor is the access password.
It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously. Once the password is typed in,
it is possible to act on the control unit by entering and exiting the programming mode for around 10 minutes in order to allow adjustments and tests
on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the access to any other menu. If a
protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
- press OK to confirm the flashing character, then confirm the following one.
- after typing in the 4 characters, a confirmation message "CONF" appears.
- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.
If the code corresponds to the previous one, a confirmation message "OK" appears.
The control unit automatically exits the programming phase. To gain access to the Menus again, the stored protection code must be typed in.
IMPORTANT: TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance operations.
To remove a code from a protected control unit it is necessary to enter into programming with the password and bring the code back to the
0000 default value.
IF YOU LOOSE THE CODE, PLEASE CONTACT THE AUTHORISED SERVICE CENTER FOR THE TOTAL RESET OF THE CONTROL UNIT.
7) OPERATING MODE WITH ENABLED/DISABLED ENCODER
With ENC=ON LOGICS:
- the anti-crash sensor is activated. The sensitivity must be adjusted through the SEAV and SEAR parameters according to regulations in force.
Once the stroke length is stored in memory by the control unit, the latter will automatically manage the braking phases during opening and closing.
The braking space can be increased or decreased by the TSM parameter. The stroke is constantly updated and stored in memory together with the
gate position in the event of power failure.
If the BLOC logics is ON, after the TSM braking time has elapsed, the stop will be delayed by around 1s when the limit switch is triggered.
With the ENC=OFF LOGICA (To be used with motors without encoder):
- the anti-crash sensor is deactivated.
- if the parameter TSM>0 (braking activated), the control unit starts the braking phase after triggering the limit switch. Duration is preset through the
parameter itself.
NB: Preset the TM parameter for a value higher than the stroke time.
In this position, the BLOC logics is irrelevant.
8) TRANSMITTER REMOTE LEARNING
If the transmitter code is already stored in the receiver, the remote radio learning can be carried out (without accessing the control unit).
IMPORTANT: The procedure should be carried out with gate in the opening phase, during the TCA dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be matched to the new transmitter. The flashing
light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at item 2. The flashing light switches off.
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
9) DIAGNOSTICS
One segment of the display is linked to each input. In the event of failure it switches on according to the
following scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the horizontal segments.

10) ERROR MESSAGES

The control unit checks the correct operation of the safety devices. In the event of failure, the following messages may be displayed:
Error, self-learning stroke:
ERR
- activation of any input by the user
- door leaf i the closing limit switch
- HTR:ON logics
- memorisation of remote controls
Check of management circuit integrity has failed
ERR1
Error, PHOTO TEST
ERR2
Encoder is broken.
ERR3
5.7) RESET (RES)
5.8 PROTECTION CODE (CODE)
SWO
SWC
P.P.
OPEN CLOSE
STOP
PHOT
DAS
EN
17