EN
INSTALLATION AND SAFETY PRECAUTIONS
The identification plate is the protecting warranty seal – DO NOT REMOVE.
The towel warmer must be installed in compliance with the manufacturer's guidelines set forth in this
user manual, only by expert technicians and installation must be compliant with all applicable rules, and
national safety regulations and laws in force in the country where the product is installed.
If the towel warmer is to be installed in a place used by the public, a warning notice should be placed
adjacent to the warmer advising that the surface can be hot.
In order to avoid a hazard for very young children, this appliance should be installed so that the lowest
heated warmer is at least 600mm above the floor.
The manufacturer does not assume any liability for any injuries caused by any changes of the
warmer construction made by any unauthorized individuals themselves.
This equipment is only purported to dry off clothing washed or damped with water.
The appliance can be used by children aged from 8 years and above.
CAUTION: The towel warmer cannot be used by any individuals, including children, with any limited
physical, sensorial or mental abilities, or by any individuals who have no experience in or knowledge
about the equipment unless it is operated under supervision or in compliance with the equipment user
manual provided by individuals responsible for their safety.
Cleaning and maintenance by the user must not be done by children without supervision.
Children must not play with the equipment.
CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has
to be given where children and vulnerable people are present. In order to be effective the towel warmer
will get hot, however momentary contact with any part of it should not cause injury.
Precautions should be taken to ensure that prolonged contact with the towel warmer cannot occur.
Radiators are heavy items and should be securely fastened to the wall. Special care should be taken
into consideration including the fixing method used to secure the radiator to the wall, the type and the
condition of the wall itself, and any additional potential forces or weights, prior to finalising installation.
The wall plugs supplied with your radiator may not be suitable for your wall type. The apropriate wall
plugs should be used by your installer. In all cases, it is strongly recommended that a suitably qualified
professional installer carries out the installation.
When connecting pipes of various materials, their difference in electrode potential may cause galvanic
corrosion and serious damage of pipes, valves and other equipment in the system. To avoid galvanic
corrosios, it is highly recommenden to use the same materials, or materials with similar electric poten-
tial, throughout loop.
- Once completed, the systems shall be properly flushed and filled in order to remove debris, sludge
and to clean solid particles and chemical residues, which may cause corrosion and damage within
systems. A good water treatment inhibitor should be used within the systems to avoid corrosion and
sludge.
- Sufficient impermeability liquid Loctite 542 must be applied to valve-tail therads prior to their installa-
tion.
- Silicone thread sealant should be applied to all threaded components manufactured with 'O-rings'.
Reaction to fire
Release of dangerous substances
Maximum surface temperature
Durability against corrosion
Pressure tightness
Ressistance to pressure
CAUTION: Hot surface
Towel warmer
For heating systems in buildings
A1
None
90ºC
No corrosion after 100h of moisture
No leakage
Without breaking
Maximum working pressure
VICTORIA
HOTEL'S
1300 kPa
520 kPa
1690 kPa
680 kPa
1000 kPa
400 kPa
towel