The sensor head can tilt about one of its axes if it is desired to displace the detection
area.
DETECTION INDICATORS
There is a red LED inside the sensors that lights when a detection is made. This
LED can be used to assist in the adjustment of the detection field without needing to
connect the load.
SETTING THE BRIGHTNESS (only in master sensor)
The DICROMAT + circuit, as well as circuit 1 of the DICROMAT 2+, can be
graduated to react only when the light conditions are below the level selected. By
rotating the brightness selector to the position "☼" they will react under any condition
of brightness. By rotating the brightness selector to the position " " they only react in
low brightness conditions. Circuit 2 (T1-T2) of the DICROMAT 2+ always reacts
independently of the regulated brightness.
For the changes made to take effect in the potentiometers in the adjustment of
the equipment, it is necessary to get out from the detection area and wait for
the installation to be turned off.
DIMENSIONS
SENSOR WIRING DIAGRAM
SETTING THE DISCONNECTION DELAY (only in master sensor)
By rotating the "Time 1" and "Time 2" selectors, the disconnection delay of the
circuits is adjusted.
TECHNICAL CHARACTERISTICS
Power supply:
Breaking power:
Recommended peak loads:
Incandescent lamps
Fluorescent tubes
Low voltage halogens (12V)
Halogens (230V)
Low consumption lamps (CFL)
Low consumption lamps (Downligts)
LED lamps
Own consumption:
Brightness range:
Timing range:
Detection angle:
Detection field:
Operating temperature:
Type of protection:
Protection class:
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Teléfono:+ 34 91 5672277;
E-mail: info@ orbis.es
http://www.orbis.es
230 V~ 50 Hz
μ 10 A 230 V~ Cos φ = 1
DICROMAT +: 7 VA capacitive (1.1 W approx.)
DICROMAT 2+: 4.2 VA capacitive (3.1 W
approx.)
2 – 2000 LUX
DICROMAT + (L ): From 1 s to 10 min.
DICROMAT 2+:
-TIME circuit 1 (L ): From 1 s to 10 min.
-TIME circuit 2 (T1-T2): From 10 s to 15 min.
360°
Up to 7 m in diameter at 2.5 m high
-10° C to +45° C
IP20 as per EN 60529
II in correct assembly conditions
E–28020 MADRID
Fax:+34 91 5714006
2200 W
400 VA
2000 VA
2200 W
400 VA
400 VA
400 VA
01_2012 / A016.13.54011