Technical Specifications; Operating Mode - Orbis ISIMAT Instrucciones De Empleo

Ocultar thumbs Ver también para ISIMAT:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The detection field can be adjusted by following these steps:
-
Rotate the switch-off delay adjustment to minimum and the ambient
light level adjustment to (☼).
-
Check coverage by moving within the detection field limits.
After installation and detection field adjustments, set the ambient light
level and switch-off delay as required.
The ISIMAT is supplied with detection area limiters. Each limiter is divided
into four sectors that can be cut according to needs. A sector is excluded
by covering the corresponding part of the lens with limiter adapted to the
actual requirements.
ADJUSTING AMBIENT LIGHT LEVEL
The ISIMAT proximity switch can be adjusted so that it only operates
when ambient light level conditions are below the selected level. By
rotating the ambient light level control to position (☼), it will react under
any lighting conditions. Setting it to position (
under very low ambient light level conditions.
To check the luminosity adjustment, it is necessary to wait until the lights
are off.
For the changes made to take effect in the potentiometers in the
adjustment of the equipment, it is necessary to get out from the
detection area and wait for the installation to be turned off.
ADJUSTING THE SWITCH-OFF DELAY
By rotating the control (
), the switch-off delay is as follows:
-
Minimum switch-off delay time: 3 seconds
-
Maximum switch-off delay time: 30 minutes.
This time is reset for each detection operation.
Detection sensitivity may be reduced if the temperature of the object
to be detected is close to the ambient temperature
When the ISIMAT delay time ends, there is a two-second period of
inactivity during which it does not detect.

OPERATING MODE

- . The unit enters normal operation thirty seconds after being switched
on.
) will mean it only reacts

TECHNICAL SPECIFICATIONS

Power supply
Breaking power
Maximum recommended loads
Incandescent lamps
Fluorescent tubes
Low voltage halogen (12 Vac)
Halogen (230 Vac)
Low consumption lamps (CFL)
Low consumption lamps (Downlights)
Led lamps
Self consumption
Ambient lighting level range
Timer range
Detection angle
Detection field
Operating temperature
Protection type
Protection class
DIMENSIONS
72
01_2012
ORBIS TECNOLOGIA ELECTRICA, S.A.
Lérida, 61
Telephone: +34 91 5672277;
230 V 50 Hz.
5 A 230 V~ cos ϕ=1
μ
1000 W
250 VA
500 VA
1000 W
200 VA
200 VA
200 VA
6 VA (1 W approx.)
5-30-2000 Lux.
from 3 s to 30 min. approx.
140º
Front: 12 metres to 20 ºC.
Lateral: 8 metres to 20 ºC.
-20 ºC to +40 ºC
IP 55 iaw EN 60529
Class II iaw EN 60669
under correct installation
conditions
100
A016.13.54551
E-28020 MADRID
Fax: +34 91 5714006
E-mail: info@ orbis.es
http://www.orbis.es
Tabla de contenido
loading