Operating Instructions; Repair Instructions - Kobalt SGY-AIR86TZ Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATION INSTRUCTIONS
Proper handling of the gun is essential for obtaining a good finish. The gun should be
held at a 90° angle to the surface being covered, and moved parallel to it. For precise
control of the gun and material, the trigger should be released before the end of the
stroke. Hold the gun 6 to 12 inches away from the surface depending on material and
atomizing pressure. For a uniform finish, lap each stroke over the preceding stroke,
making sure the spray is smooth and wet. Using the lowest possible atomizing air
pressure will reduce over spray and provide maximum efficiency. (See Figure 7)
7
6 to 12 inches
Start
stroke

REPAIR INSTRUCTIONS

Remove air pressure from air hose / gun.
CAUTION:
Take care not to damage the seals on the gun body when removing the
air distribution ring.
1. Remove the nozzle set:
a. Remove air cap w/ring. (See Figure 1)
b. Unscrew the fluid adjustment knob. (See Figure 2)
c. Pull out needle spring and paint needle. (See Figure 3)
d. Remove paint nozzle using wrench provided. (See Figure 4)
1
4
Even and wet coat
Pull
trigger
RIGHT
2
Light coat
Release
End of
trigger
stroke
3
8
Heavy coat
WRONG
Tabla de contenido

Solución de problemas

loading

Tabla de contenido