ELECTRIC SYSTEM
3.3- Electric CONTROL BOARD GL-W123 / 24V
FUSE
F1
LOW LOWER EVAP. 2
F2
LOW LOWER EVAP. 1
F3
HIGH LOWER EVAP. 1
F4
HIGH LOWER EVAP. 2
F5
HIGH LOWER EVAP. 3
F6
CLUTCH
F7
N.C.
F8
LOW LOWER EVAP. 3
F9
CONDENSER 5
F10
N.C.
F11
CONDENSER 1
F12
CONDENSER 2
F13
CONDENSER 3
F14
VALVE OF LIQUID
F15
CONDENSER 4
F16
CONDENSER 6
F17
N.C.
OBSERVATION: as you are handling with commutation high current electric device, it is necessary to install it in a
ventilated point, not closed built, far from fuel, inflammable lines, risky spot, fire and explosion material. The device is
not waterproof. Water spray and drops can damage it.
RELÉS
10A
RL1 CONDENSER CONTROL
10A
RL2 LOW LOWER EVAP. CONTROL
15A
RL3 LOW LOWER EVAP. 1 AND 2
15A
RL4 HIGH LOWER EVAP. CONTROL
15A
RL5 HIGH LOWER EVAP. 1
5A
RL6 HIGH LOWER EVAP. 2
RL7 HIGH LOWER EVAP. 3
10A
RL8 CLUTCH
20A
RL9 LOW LOWER EVAP. 3
RL10 VALVE OF LIQUID
20A
RL11 CONDENSER 5
20A
RL12 CONDENSER 1
20A
RL13 CONDENSER 2
5A
RL14 CONDENSER 3
20A
RL15 CONDENSER 4
20A
RL16 CONDENSER 6
1 - + 24VBAT
2 – GROUND
3 – Low lower evap. commun.
MALE CONNECTION
4 - High lower evap. commun.
6 WAY MOLEX
REF. 3901-2060
5 - Valve of liquid commun.
6 - Condenser commun.
FEMALE TERMINAL
MINI FIT MOLEX
3
2
REF. 3900-0059
6
9
8
9 WAY FEMALE CONNECTOR
ref. AMP: 880125-0
Plant code: 007-00023-000
1 - Clutch
3,5A@28VDC
2 - High lower evap. 3
11A@28VDC
3 - High lower evap. 2
11A@28VDC
4 – N.C.
5 - D+ (OPTIONAL)
6 - High lower evap. 1
11A@28VDC
7 - Low lower evap. 3
7,5A@28VDC
8 - Low lower evap. 2
7,5A@28VDC
9 - Low lower evap. 1
7,5A@28VDC
1 - Condenser 4
11A@28VDC
2 - Condenser 3
11A@28VDC
3 - Condenser 2
11A@28VDC
4 - Condenser 6
11A@28VDC
5 - Valve of liquid
3,5A@28VDC
6 - Condenser 1
11A@28VDC
7 – N.C.
8 - Condenser 5
11A@28VDC
9 – N.C.
1
5
7
4
MALE TERMINAL
FOR CABLES
from 0.5 up to 2.5 mm
2
ref. AMP: 880685-2
DD 430
55