Maintenance (Continued)
Disconnect the air supply from the tool to add lubricant.
Turn the tool so the air inlet is facing up. Place 2-3 drops
of pneumatic fastening tool oil into the air inlet. Do not
use detergent oils, oil additives, or air -tool oils. Do not
use detergent oil or additives as these lubricants will
cause accelerated wear to the seals and bumpers in the
tool, resulting in poor tool performance and frequent tool
maintenance.
After adding oil, run the tool briefly. Wipe off any excess
oil from the cap exhaust.
CAUTION: Lubricate the tool only with specified
lubricants.
CAUTION: The work surface can become damaged by
excessive lubrication. Proper lubrication is the owner's
responsibility. Failure to lubricate the tool properly will
dramatically shorten the life of the tool and void your
warranty.

Cleaning

Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and maybe damaged by their use. Use
clean cloths to remove dirt, dust , oil, grease, etc.
CAUTION: Do not at any time let brake fluids, gasoline,
petroleum-based products, penetration oils ect. come
in contact with plastic parts. Chemicals can damage,
weaken or destroy plastic which may result in serious
personal injury.

Cold weather operation

For cold weather operation, near and below freezing, the
moisture in the air line may freeze and prevent tool
operation. We recommend the use of air tool lubricant or
permanent antifreeze (ethylene glycol) as a cold weather
lubricant.
CAUTION: Do not store tools in a cold weather
environment to prevent frost or ice formation on the
tools' operating valves and mechanisms that could
cause tool failure.
12

Recommended hookup

The air compressor must be able to maintain a minimum
of 70 psi when the tool is being used. An inadequate air
supply can cause a loss of power and inconsistent
driving.
An oiler can be used to provide oil circulation through the
tool. A filter can be used to remove liquid and solid
impurities which can rust or gum up internal parts of the
tool.
Always use air supply hoses with a minimum working
pressure rating equal to or greater than the pressure from
the power source if a regulator fails, or 150 psi, whichever
is greater. Use 3/8 in. air hose for runs up to 50 ft. and use
a 3/8 in. quick coupler on the air hose.
Use a pressure regulator on the compressor, with an
operating pressure of 0-125 psi. A pressure regulator is
required to control the operating pressure of the tool
between 70 psi and 115 psi.
Quick
Coupler
Air hose
Quick
connector
CAUTION: The air compressor must be able to
maintain a minimum of 70 psi when the tool is being
used. An inadequate air supply can cause a loss of
power and inconsistent driving.
WARNING: Do not connect with an air compressor
which can potentially exceed 200 psi. The tool may
burst, possibly causing injury.
Quick
Filter
Oiler
connector
Compressor
Quick
Regulator
Coupler
13
Please contact 1-888-HD-HUSKY for further assistance.
HUSKYTOOLS.COM