Preparation (cont.)
NOTE: Some Kohler faucets require a minimum of 2-1/2" (6.4cm)
behind the final faucet centerline.
Cut along the backsplash locator line on the template.
Cut out the template along the inside of the template cut-out line
labeled "Self-Rimming Cut-Out".
Position the template on the countertop to ensure clearance
between the lavatory, faucet, and backsplash.
Verify cabinet clearance beneath the countertop.
Use a pencil to trace the template on the countertop.
Check the clearance between the lavatory, faucet, backsplash, and
cabinet. Adjust the traced cut-out line accordingly.
Mark the faucet and handle centerline on the countertop.
Above-Counter Installation
Cut out the template along the inside of the template cut-out line
labeled "Above-Counter Cut-Out".
Position the template on the countertop.
For Wall-Mount Faucets: Provide sufficient spout overhang into
the lavatory basin. The faucet spout length must be at least 5"
(12.7cm) to provide proper performance.
For Countertop Faucets: Pay special attention to the spout and
handle fit clearance when locating the faucet. Use the template to
locate the faucet spout hole centerline on the countertop. This
centerline is recommended to provide adequate clearance
between the edge of the lavatory and the spout.
Check for adequate clearance between the backsplash, faucet
spout and handles, and lavatory. Kohler Co. recommends a
clearance of at least 1" (2.5cm). See illustration.
Refer to the faucet installation instructions for required clearance,
and mark the preferred faucet hole locations using a soft lead
pencil.
Trace the template on the countertop.
1018375-2-A
4
Kohler Co.