Technical Data

Power Unit
Article number
Battery chemistry
Rated capacity
Nominal battery voltage
Charging time (100 %)
Input voltage
Output voltage
– Combined mode
– Inverting mode
Frequency
Output Power*/**
– Inverting mode
– Combined mode
Input power*/**
– Charging Power
– Combined mode

Working Advice

Inspection before work
Before each operation conduct an inspection of the product covering the following steps:
Designation
Inspect product housing, sockets, overload reset
cover, and LCD screen with on/off button and power
cables
Tighten all product underneath screws to frame, hub
plate bolts and wheel nuts (if applicable)
Examine the two wheels with tyres (if applicable)
Cleaning of product using a soft brush
Check the battery charge level
Recharge the product before long term storage*
* If stored longer than 6 months, consider periodically charging the product above 60 %
Before use, inspect the input and output sockets, overload re-
set cover, and LCD screen with the on/off button. If damage is
detected, do not use the product.
Before each use examine the product power lead with plug
and that of any auxiliary equipment to be fitted. If damage is
detected, do not use the product; replace the faulty power
lead with plug before use.
Check the product housing inside the frame, the frame unit
and the wheel kits (if applicable). If damage is detected, do
not use the product.
Bosch Power Tools
Power Unit
Allowable ambient temperature
GEN 230V-1500
limits ***
EEU
0 600 915 000
Cooling
UK
0 600 915 070
Degree of protection ****
CH
0 600 915 030
Weight according to EPTA-
LiFeYPO4
Procedure 01:2014
Lithium Iron
Protection class
Phosphate
– Charging power
Wh
1650
– Inverting mode
V
16.5
– Combined mode
min
180
The values given are valid for nominal voltages [U] of
V
220–240
220 – 240 V. For lower voltage and models for specific
countries, these values can vary.
V
220–240
* For extended product life, we recommend that the product
V
230
is operated at no higher than 1200 W
Hz
50
** At 1500 W runtime is <2 minutes
*** A higher ambient temperature could shorten the lifespan
W
1500
of the product- battery
W
1500
**** The product is only IP54 rated in inverter mode and with
appropriate IP rated EU plug/UK adapter.
W
600
W
1600
Daily
Keep all nuts, bolts and screws tight to be sure that the prod-
uct is in safe working condition.
Ensure that only official Bosch replacement parts are used.

Operation Modes

The product is a device, which can operate in three different
modes:
Inverting mode: In inverter mode the product is powered by
the on/off button and provides 230 V/AC power to the two
outlet sockets from the internal battery.
GEN 230V-1500
°C
kg
Weekly
Monthly
1 609 92A 3EZ | (27.10.16)
English | 15
0–40
Forced Air
IP 54
42,0
I
II
I
Annually