TECHNICAL DATA
1.
Transformer
24 VAC internal transformer; 20 VA, .83A for zones and logic. The transformer
can run a pump or master valve and one zone valve, maximum.
2.
Surge Protection
600 watts TVS on zone outputs 9J Mov on secondaries.
(see Circuit Breaker below)
3.
Sensor Operation
™
The EZ Pro
without a sensor. Sensors must have normally closed connections (leads).
The factory-installed jumper wire must be in place if no ensor is used.
4.
Zone Lines
™
The EZ Pro
concurrently, providing one is the pump/master valve. Each zone output can
operate one or two solenoids.
I inrush .52A max
I hold .33A max
5.
Temperature Range
Operating: -20° to +55° C (23° to 131° Fahrenheit)
Storage: -30° to +85° C (-22° to 185° Fahrenheit)