SAFETY and GENERAL INFORMATION
Save these instructions. For your safety, read and understand the information contained within. The owner and
operator shall have an understanding of this product and safe operating procedures before attempting to use this
product. Make certain that the operator thoroughly understands the inherent dangers associated with the use and
misuse of the product. If any doubt exists as to the safe and proper use of this product as outlined in this factory
authorized manual, remove from service immediately.
Inspect before each use. It is recommended that, prior to each use, an inspection be done by qualified personnel
and that any missing or damaged parts, decals, warning / safety labels or signs be replaced with factory authorized
replacement parts only. Any pump that appears to be damaged in any way, is worn, leaking or operates abnormally
shall be removed from service immediately until such time as repairs can be made. Any pump that has been or
suspected to have been subject to a shock load (a load dropped suddenly, causing the system pressure to exceed
10,000 PSI), shall be removed from service immediately until checked by qualified personnel. Owners and operators
of this equipment shall be aware that the use and subsequent repair of this equipment may require special training
and knowledge. Labels and operator's manuals are available from the manufacturer.
PRODUCT DESCRIPTION
Air Foot Pumps are engineered to meet industry standards for performance and safety.
ply compressed hydraulic fluid to compatible applications i.e. rams, presses, spreaders, compactors and crimping
machines, anywhere that 10,000 PSI (700 Bar) of fluid pressure is needed.
may be required for a specific task and the product may not be suitable for all the jobs described above. Unsuitable
applications would include applications that call for a device to move, level or support persons, animals, hazardous
materials, mobile homes/ dwellings in general, mirrors and/or plate glass, and/or to connect/secure hatches, com-
ponents, etc. between bulkheads. The user must ultimately make the decision regarding suitability of the product for
any given task and assume the responsibility of safety for himself and others in the work area.
!
To reduce the risk of personal injury and/or property damage, ensure that the rated working pressure of each
pressurized attachment be equal to or greater than the rated working pressure developed by the hydraulic pump.
!
Always check connections before using. Alteration of these products is strictly prohibited. Use only those adapters and
attachments provided and approved by the manufacturer.
SPECIFICATIONS
Usable Oil
Model
Capacity
Number
(in
)
3
5100784
91.5
5100785
122
Foot Pedal
Input Port
(air)
Figure 1 - Model 5100784 Components
Output Flow Rate
Rated
(in
/min)
3
Pressure
(PSI)
No Load
66
10,000
65
Output Port
(fluid, not shown)
Reservoir
Input Air
Pressure
(PSI)
Load
11
110 - 175
12
Input Port
(air)
Figure 2 - Model 5100785 Components
2
Foot actuated pumps sup-
Special skill, knowledge and training
Output Port
Input Port
Thread
Threads
(Oil)
3/8" - 18NPTF
1/4" - 18NPT
Foot Pedal
(Air)
Output Port
(fluid, not
shown)
Reservoir